Changes in oxygen measurements when whole blood is stored in iced plastic or glass syringes.

J J Mahoney1, J A Harvey, R J Wong, A L Van Kessel.   

Abstract

Tonometered whole-blood and plasma specimens were tested in plastic and glass syringes to determine whether clinically significant changes in gas tensions occur during sample storage. When whole blood was tonometered with 60 and 100 mL/L (6% and 10%) oxygen and then stored for 30 min in iced plastic syringes, the pO2 of the samples remained stable (mean change = +0.4 and +0.8 mmHg, respectively). However, for 140 mL/L (14%) oxygen tonometry, the pO2 increased significantly (mean change = +8.4 mmHg; P less than 0.0001). When tonometered plasma was stored in iced plastic syringes, the pO2 increased progressively at all three concentrations, with the smallest change occurring at 140 mL/L (mean change = +12.6 mmHg) and the greatest at 60 mL/L oxygen (mean change = +20.9 mmHg). In contrast, when iced glass syringes were used for storing plasma or whole blood, no clinically significant changes in pO2 were found at any of the tonometered oxygen values for 60 min. When whole blood was stored in plastic syringes at ambient temperature for 30 min, again no clinically significant changes in pO2 were found at these tonometry conditions. Apparently, some blood gas samples stored in iced plastic syringes may yield clinically significant errors in oxygen tension.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1823532

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  7 in total

1.  Detection of preanalytical errors in arterial blood gas analysis.

Authors:  Serap Çuhadar; Hayat Özkanay-Yörük; Mehmet Köseoğlu; Kaan Katırcıoğlu
Journal:  Biochem Med (Zagreb)       Date:  2022-06-15       Impact factor: 2.515

2.  Aqueous humor oxygen measurements.

Authors:  Alexander Nguyen; Ying-Bo Shui; Qianru Zhang; David C Beebe; Carla J Siegfried
Journal:  J Glaucoma       Date:  2013 Oct-Nov       Impact factor: 2.503

3.  Effects of sample storage time, temperature and syringe type on blood gas tensions in samples with high oxygen partial pressures.

Authors:  J J Pretto; P D Rochford
Journal:  Thorax       Date:  1994-06       Impact factor: 9.139

4.  Clinical evaluation of a multiparameter intra-arterial blood-gas sensor.

Authors:  E Abraham; T J Gallagher; S Fink
Journal:  Intensive Care Med       Date:  1996-05       Impact factor: 17.440

5.  Influence of different storage times and temperatures on blood gas and acid-base balance in ovine venous blood.

Authors:  H A Hussein; A A Aamer
Journal:  Open Vet J       Date:  2013-01-03

6.  Stability of hematological parameters of canine blood samples stored with citrate phosphate dextrose adenine-1 anticoagulated plastic vacutainers.

Authors:  Okereke Henry Nnamdi; Udegbunam Rita Ijeoma; Nnaji Theophilus Okaforx
Journal:  Vet World       Date:  2019-03-25

7.  Stability of pH, Blood Gas Partial Pressure, Hemoglobin Oxygen Saturation Fraction, and Lactate Concentration.

Authors:  Ariadna Arbiol-Roca; Claudia Elizabeth Imperiali; Dolors Dot-Bach; José Valero-Politi; Macarena Dastis-Arias
Journal:  Ann Lab Med       Date:  2020-06-17       Impact factor: 3.464

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.