Literature DB >> 18234594

Measurement-Dependent Filtering: A Novel Approach to Improved SNR.

A Macovski, D G Nishimura, A Doost-Hoseini, W R Brody.   

Abstract

Recently, a variety of medical imaging systems have been introduced involving selective imaging using multiple measurements. In these systems a number of independent measurements, taken at different times and/or using different X-ray energies, are combined to form a selective image. A prime example is the selective imaging of iodine for vessel imaging. These systems, involving subtraction operations, result in a degradation of the SNR, as compared to the individual measurements. In this approach called measurement-dependent filtering, the low spatial frequencies are derived from the selective image and the high frequencies from a nonselective combination of the measurements which has a greater SNR. The combination provides a significantly improved SNR with the original resolution and a degree of "conspicuity" essentially equal to selective image.

Entities:  

Year:  1983        PMID: 18234594     DOI: 10.1109/TMI.1983.4307625

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Adaptive noise correction of dual-energy computed tomography images.

Authors:  Rafael Simon Maia; Christian Jacob; Amy K Hara; Alvin C Silva; William Pavlicek; J Ross Mitchell
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-13       Impact factor: 2.924

2.  An algorithm for noise correction of dual-energy computed tomography material density images.

Authors:  Rafael Simon Maia; Christian Jacob; Amy K Hara; Alvin C Silva; William Pavlicek; Mitchell J Ross
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-05-11       Impact factor: 2.924

3.  An effective noise reduction method for multi-energy CT images that exploit spatio-spectral features.

Authors:  Zhoubo Li; Shuai Leng; Lifeng Yu; Armando Manduca; Cynthia H McCollough
Journal:  Med Phys       Date:  2017-04-12       Impact factor: 4.071

4.  Noise Suppression for Dual-Energy CT Through Entropy Minimization.

Authors:  Michael Petrongolo; Lei Zhu
Journal:  IEEE Trans Med Imaging       Date:  2015-05-01       Impact factor: 10.048

5.  Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study.

Authors:  Bitbyeol Kim; Ho Kyung Kim; Jinsung Kim; Yongkan Ki; Ji Hyeon Joo; Hosang Jeon; Dahl Park; Wontaek Kim; Jiho Nam; Dong Hyeon Kim
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2021-09-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.