A novel noninvasive measurement technique for analyzing the pressure pulse waveform of the radial artery.

Chu-Chang Tyan1, Shing-Hong Liu, Jan-Yow Chen, Jian-Jung Chen, Wen-Miin Liang.   

Abstract

Previous noninvasive measurements of the pulse waveform of the radial artery have not employed standard positioning procedures. Here, we propose a new noninvasive measuring apparatus that has a two-axis mechanism and employs a standard positioning procedure for detecting the optimal site for accurately measuring the pressure pulse waveform (PPW). A modified sensor was designed to simultaneously measure the arterial diameter changed waveform (ADCW) and PPW. Considering the artery as a cylinder, the measured waveform would be distorted if the sensor were not at the middle of arterial width. Moreover, a blood vessel is elastic, and its compliance changes with the transmural pressure, being maximal when the transmural pressure is equal to zero. The sensor should detect the PPW with the lowest possible distortion and, hence, an analysis of the vascular geometry and an arterial model were used to design a standard positioning procedure based on the ADCW for the X and Z axes. In order to verify the resolution of the X axis scanning procedure, the echo method was used to measure the radial artery outer diameter in ten healthy subjects. The difference between the scanning width and the actual arterial diameter was 0.36 +/- 0.23 mm (mean +/- SD). Finally, the PPW as measured at the optimal position was used to diagnose myocardial ischemia symptoms in 60 elderly subjects whose chief complaint was chest pain, with the exercise electrocardiogram being used as a reference to compare between individuals with and without myocardial ischemia. The PPW analysis used the harmonic components in the frequency domain. We found that the fourth harmonic of the Fourier series differed significantly between the groups (p = 0.0039), which is consistent with previous studies. The results indicate that our noninvasive measurement apparatus is very suitable for analyzing the PPW of the radial artery.

Entities:  

Mesh:

Year:  2008        PMID: 18232373     DOI: 10.1109/TBME.2007.910681

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  12 in total

1.  Stringlike pulse quantification study by pulse wave in 3D pulse mapping.

Authors:  Ching-Hsing Luo; Yu-Feng Chung; Cheng-Chang Yeh; Xiao-Chen Si; Chien-Chen Chang; Chung-Shing Hu; Yu-Wen Chu
Journal:  J Altern Complement Med       Date:  2012-10       Impact factor: 2.579

2.  Temporal and spatial properties of arterial pulsation measurement using pressure sensor array.

Authors:  Chung-Shing Hu; Yu-Feng Chung; Cheng-Chang Yeh; Ching-Hsing Luo
Journal:  Evid Based Complement Alternat Med       Date:  2011-06-30       Impact factor: 2.629

3.  Effect of hot-attribute aged ginger tea on chinese medical pulse condition of healthy young humans.

Authors:  Dan-Ping Chao; Chu-Chang Tyan; Jian-Jung Chen; Ching-Liang Hsieh; Lee-Yan Sheen
Journal:  J Tradit Complement Med       Date:  2011-10

4.  Assessment of the endothelial function with changed volume of brachial artery by menstrual cycle.

Authors:  Shing-Hong Liu; Jia-Jung Wang; Da-Chuan Cheng; Chun-Hung Su; Tzu-Hsin Lin
Journal:  Biomed Eng Online       Date:  2016-09-06       Impact factor: 2.819

5.  Three-Dimensional Arterial Pulse Signal Acquisition in Time Domain Using Flexible Pressure-Sensor Dense Arrays.

Authors:  Jianzhong Chen; Ke Sun; Rong Zheng; Yi Sun; Heng Yang; Yifei Zhong; Xinxin Li
Journal:  Micromachines (Basel)       Date:  2021-05-17       Impact factor: 2.891

6.  Portable Interactive Pulse Tactile Recorder and Player System.

Authors:  Tzu-Chieh Hsieh; Chien-Min Wu; Cheng-Chung Tsai; Wen-Chien Lo; Yu-Min Wang; Shana Smith
Journal:  Sensors (Basel)       Date:  2021-06-25       Impact factor: 3.576

7.  Quantitative analysis of sensor for pressure waveform measurement.

Authors:  Shing-Hong Liu; Chu-Chang Tyan
Journal:  Biomed Eng Online       Date:  2010-01-21       Impact factor: 2.819

8.  Pulse waveform classification using support vector machine with Gaussian time warp edit distance kernel.

Authors:  Danbing Jia; Dongyu Zhang; Naimin Li
Journal:  Comput Math Methods Med       Date:  2014-02-09       Impact factor: 2.238

9.  A Novel Method for Pulsometry Based on Traditional Iranian Medicine.

Authors:  Farzane Yousefipoor; Vahidreza Nafisi
Journal:  J Med Signals Sens       Date:  2015 Oct-Dec

10.  Different Harmonic Characteristics Were Found at Each Location on TCM Radial Pulse Diagnosis by Spectrum Analysis.

Authors:  Yun-Ning Tsai; Yi-Chia Huang; Sunny Jui-Shan Lin; Shen-Ming Lee; Yung-Yen Cheng; Yu-Hsin Chang; Yi-Chang Su
Journal:  Evid Based Complement Alternat Med       Date:  2018-07-05       Impact factor: 2.629

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.