Literature DB >> 18230455

Comments, with reply, on ;Tomographic reconstruction from experimentally obtained cone-beam projections' by S. Webb, et al.

L A Feldkamp1, L C Davis, S Webb.   

Abstract

The above paper (ibid., vol.MI-6, p.67-73, 1987) purports to propose an algorithm and implementation formulas for cone-beam reconstruction. The commenters point out that the exposition of the paper is little more than a paraphrase of their own earlier work (J. Opt. Soc. Amer. A, vol.1, no.6, p.612-19, 1984). All the benefits claimed are intrinsic to the algorithm proposed and were pointed out in the commenters paper. Webb et al. also suggest the use of a modified convolution scheme previously proposed for fan-beam reconstruction. Use of this scheme does not alter the basic premise of the commenters' work and does not entitle Webb et al. to claim to have developed a new algorithm. The authors reply that their paper presents experimental results that are based on the commenters' theoretical results, which were cited in the formers' paper.

Entities:  

Year:  1988        PMID: 18230455     DOI: 10.1109/42.3930

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

Review 1.  [Application of C-arm computed tomography in cardiology].

Authors:  J Rieber; C Rohkohl; G Lauritsch; H Rittger; O Meissner
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

Review 2.  New X-ray imaging modalities and their integration with intravascular imaging and interventions.

Authors:  H Hetterich; T Redel; G Lauritsch; C Rohkohl; J Rieber
Journal:  Int J Cardiovasc Imaging       Date:  2009-11-08       Impact factor: 2.357

3.  Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography.

Authors:  Niccolò Faccioli; Giovanni Foti; Marco Barillari; Andrea Atzei; Roberto Pozzi Mucelli
Journal:  Skeletal Radiol       Date:  2010-03-12       Impact factor: 2.199

4.  Direct comparison of conventional radiography and cone-beam CT in small bone and joint trauma.

Authors:  E De Smet; G De Praeter; K L A Verstraete; K Wouters; Luc De Beuckeleer; F M H M Vanhoenacker
Journal:  Skeletal Radiol       Date:  2015-03-12       Impact factor: 2.199

5.  18F-sodium fluoride positron emission tomography assessed microcalcifications in culprit and non-culprit human carotid plaques.

Authors:  H Hop; S A de Boer; M Reijrink; P W Kamphuisen; M H de Borst; R A Pol; C J Zeebregts; J L Hillebrands; R H J A Slart; H H Boersma; J Doorduin; D J Mulder
Journal:  J Nucl Cardiol       Date:  2018-06-25       Impact factor: 5.952

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.