BACKGROUND: Supraglottic airway devices are increasingly important in clinical anesthesia and prehospital emergency medicine, but there are only few data to assess the risk for aspiration. We designed this study to compare the seal of seven supraglottic airway devices in a cadaver model of elevated esophageal pressure.
METHODS: The classic laryngeal mask airway, laryngeal mask airway ProSeal, intubating laryngeal mask airway Fastrach, laryngeal tube, laryngeal tube LTS II, Combitube, and Easytube were inserted into unfixed human cadavers with an exposed esophagus that had been connected to a water column of 130 cm height. Slow and fast increases of esophageal pressure were performed and the water pressure at which leakage appeared was registered.
RESULTS: The Combitube, Easytube, and intubating laryngeal mask Fastrach withstood the water pressure up to more than 120 cm H2O. The laryngeal mask airway ProSeal, laryngeal tube, and laryngeal tube LTS II were able to block the esophagus until 72-82 cm H2O. The classic laryngeal mask airway showed leakage at 48 cm H2O, but only minor leakage was found in the trachea. Devices with an additional esophageal drain tube drained fluid sufficiently without pulmonary aspiration.
CONCLUSIONS: Concerning the risk of aspiration, the use of devices with an additional esophageal drainage lumen might be superior for use in patients with an increased risk of aspiration. The Combitube, Easytube, and intubating laryngeal mask Fastrach showed the best capacity to withstand an increase of esophageal pressure.

Entities:  

Mesh:

Year:  2008        PMID: 18227299     DOI: 10.1213/ane.0b013e3181602ae1

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  20 in total

1.  [Rapid sequence induction and intubation in patients with risk of aspiration : Recommendations for action for practical management of anesthesia].

Authors:  C Eichelsbacher; H Ilper; R Noppens; J Hinkelbein; T Loop
Journal:  Anaesthesist       Date:  2018-06-29       Impact factor: 1.041

2.  [Securing the airway in emergencies].

Authors:  Michael Frass
Journal:  Wien Klin Wochenschr       Date:  2008       Impact factor: 1.704

3.  [Supraglottic airway devices in emergency medicine : impact of gastric drainage].

Authors:  V Mann; S T Mann; E Alejandre-Lafont; R Röhrig; M A Weigand; M Müller
Journal:  Anaesthesist       Date:  2013-03-16       Impact factor: 1.041

4.  Passive continuous positive airway pressure ventilation during cardiopulmonary resuscitation: a randomized cross-over manikin simulation study.

Authors:  Bernd E Winkler; Ralf M Muellenbach; Thomas Wurmb; Manuel F Struck; Norbert Roewer; Peter Kranke
Journal:  J Clin Monit Comput       Date:  2016-02-09       Impact factor: 2.502

Review 5.  Current status of the EasyTube: a review of the literature.

Authors:  Sonia J Vaida; Luis A Gaitini; Michael Frass; Jansie Prozesky
Journal:  Rom J Anaesth Intensive Care       Date:  2015-04

6.  Prevention of aspiration of gastric contents during attempt in tracheal intubation in the semi-lateral and lateral positions.

Authors:  Ichiro Takenaka; Kazuyoshi Aoyama
Journal:  World J Emerg Med       Date:  2016

7.  PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy.

Authors:  Bimla Sharma; Raminder Sehgal; Chand Sahai; Jayashree Sood
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2010-10

8.  Survey of Accepted Practice following Failed Intubation for Emergency Caesarean Delivery.

Authors:  Daniel Soltanifar; David Bogod; Sally Harrison; Brendan Carvalho; Pervez Sultan
Journal:  Anesthesiol Res Pract       Date:  2015-03-10

9.  Comparison of intragastric pressure between endotracheal tube and supraglottic airway devices in laparoscopic hepatectomy: A randomized, controlled, non-inferiority study.

Authors:  Jin Hee Ahn; Ji Seon Jeong; Se Hee Kang; Ji Eun Yeon; Eun A Cho; Gyu Sung Choi; Jong Man Kim; Gaab Soo Kim
Journal:  Medicine (Baltimore)       Date:  2021-06-18       Impact factor: 1.817

10.  Extraglottic airway devices: A review.

Authors:  Ramesh Ramaiah; Debasmita Das; Sanjay M Bhananker; Aaron M Joffe
Journal:  Int J Crit Illn Inj Sci       Date:  2014-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.