Literature DB >> 18220483

Cohort study of the pathogenesis and molecular epidemiology of catheter-related bloodstream infection in neonates with peripherally inserted central venous catheters.

Jeffery S Garland1, Colleen P Alex, Jackie M Sevallius, Dawn M Murphy, Mary J Good, Annette M Volberding, Leslie L Hofer, Barbara J Gordon, Dennis G Maki.   

Abstract

OBJECTIVE: To better define the pathogenesis of catheter-related bloodstream infection (BSI) in neonates with peripherally inserted central venous catheters (PICCs) to guide the development of more effective strategies for prevention.
DESIGN: Prospective nested cohort study.
SETTING: Level III neonatal intensive care unit in a community hospital.
METHODS: During a randomized trial to assess the safety and efficacy of a prophylactic vancomycin-heparin catheter-lock solution for the prevention of catheter-related BSI in neonates with PICCs, we performed cultures of peripheral and catheter-drawn blood samples, and quantitative cultures of catheter hub samples if BSI was suspected clinically. We performed semiquantitative cultures of the catheter tip and the catheter hub and the skin at the insertion site when the catheter was removed. Molecular subtyping by pulsed-field electrophoresis was used to determine the probable pathogenesis of all BSIs due to coagulase-negative staphylococci (CoNS); for BSIs caused by other microorganisms, epidemiologic concordance was based on speciation and antibiograms. Catheter-related BSI was considered extraluminally acquired if concordance was demonstrable solely between isolates recovered from the catheter tip and the blood, independent of concordance with isolates recovered from the insertion site. Catheter-related BSI was considered intraluminally acquired if concordance was demonstrated only between isolates recovered from the catheter hub and the blood. The source of the infection was considered indeterminate if both concordance patterns were present.
RESULTS: Nosocomial BSI was identified in 23 of the 82 neonates in the cohort. Fifteen of these infections, 14 of which were caused by CoNS, were considered definite or probable catheter-related BSIs. Catheter-related BSI was intraluminally acquired in 10 (67%) of 15 patients, extraluminally acquired in 3 (20%), and indeterminate in 2 (13%).
CONCLUSIONS: Most catheter-related BSIs in neonates with PICCs are caused by CoNS and derive from intraluminal contamination. Strategies for prevention of catheter-related BSI directed at this predominant mechanism of infection are most likely to be effective.

Entities:  

Mesh:

Year:  2008        PMID: 18220483     DOI: 10.1086/526439

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  18 in total

Review 1.  Risk factors and prevention of late-onset sepsis in premature infants.

Authors:  L Corbin Downey; P Brian Smith; Daniel K Benjamin
Journal:  Early Hum Dev       Date:  2010-01-29       Impact factor: 2.079

Review 2.  Understanding the significance of Staphylococcus epidermidis bacteremia in babies and children.

Authors:  Gordon Y C Cheung; Michael Otto
Journal:  Curr Opin Infect Dis       Date:  2010-06       Impact factor: 4.915

3.  Catheter dwell time and CLABSIs in neonates with PICCs: a multicenter cohort study.

Authors:  Aaron M Milstone; Nicholas G Reich; Sonali Advani; Guoshu Yuan; Kristina Bryant; Susan E Coffin; W Charles Huskins; Robyn Livingston; Lisa Saiman; P Brian Smith; Xiaoyan Song
Journal:  Pediatrics       Date:  2013-11-11       Impact factor: 7.124

4.  Risk Factors for Late-Onset Sepsis in Preterm Infants: A Multicenter Case-Control Study.

Authors:  Sofia El Manouni El Hassani; Daniel J C Berkhout; Hendrik J Niemarkt; Sarah Mann; Willem P de Boode; Veerle Cossey; Christian V Hulzebos; Anton H van Kaam; Boris W Kramer; Richard A van Lingen; Johannes B van Goudoever; Daniel C Vijlbrief; Mirjam M van Weissenbruch; Marc A Benninga; Nanne K H de Boer; Tim G J de Meij
Journal:  Neonatology       Date:  2019-04-04       Impact factor: 4.035

Review 5.  Early removal versus expectant management of central venous catheters in neonates with bloodstream infection.

Authors:  Chakrapani Vasudevan; Sam J Oddie; William McGuire
Journal:  Cochrane Database Syst Rev       Date:  2016-04-20

6.  Persistent coagulase-negative staphylococci bacteremia in very-low-birth-weight infants.

Authors:  Nehama Linder; Adriana Hernandez; Limor Amit; Gil Klinger; Shai Ashkenazi; Itzhak Levy
Journal:  Eur J Pediatr       Date:  2011-01-08       Impact factor: 3.183

7.  Preventive application of low molecular weight heparin ameliorates peripherally inserted central catheter-related venous thrombosis.

Authors:  Liquan Huang; Guiyuan Chen; Bo Hu; Shuxia Liang; Wenya Chu; Li Chen
Journal:  Int J Clin Exp Pathol       Date:  2020-03-01

8.  Evaluation of Skin Colonisation And Placement of vascular access device Exit sites (ESCAPE Study).

Authors:  Nancy L Moureau; Nicole Marsh; Li Zhang; Michelle J Bauer; Emily Larsen; Gabor Mihala; Amanda Corley; India Lye; Marie Cooke; Claire M Rickard
Journal:  J Infect Prev       Date:  2018-11-09

Review 9.  Antimicrobial-impregnated central venous catheters for prevention of catheter-related bloodstream infection in newborn infants.

Authors:  Munisha Balain; Sam J Oddie; William McGuire
Journal:  Cochrane Database Syst Rev       Date:  2015-09-27

Review 10.  Percutaneous central venous catheters versus peripheral cannulae for delivery of parenteral nutrition in neonates.

Authors:  Sean Ainsworth; William McGuire
Journal:  Cochrane Database Syst Rev       Date:  2015-10-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.