Literature DB >> 18216025

Performance evaluation of field-in-field technique for tangential breast irradiation.

Jeong-Woo Lee1, Semie Hong, Kyoung-Sik Choi, Yon-Lae Kim, Byung-Moon Park, Jin-Beom Chung, Doo-Hyun Lee, Tae-Suk Suh.   

Abstract

Conventional hard or dynamic wedge systems are commonly applied to reduce the dose inhomogeneity associated with whole breast irradiation. We evaluated the dosimetric benefits of the field-in-field (FIF) technique by comparing it with the electronic compensator (EC), Varian enhanced dynamic wedge (EW) and conventional hard wedge (HW) techniques. Data were obtained from 12 patients who had undergone breast-conserving surgery (six left-sided and six right-sided). For these patients, the average breast planning target volume (PTV) was 447.4 cm(3) (range, 211.6-711.8 cm(3)). For the experiments, a 6 MV photon beam from a Varian 21 EX was used, the HW and EW angles were applied from 15 to 45 degrees, while 40-50% isodose values were chosen to achieve the best dose distribution for electronic compensation. In applying the FIF technique, we used two or three subfields for each portal. To evaluate the performance for each planning technique, we analysed a dose-volume histogram (DVH) for the PTV and organs-at-risk (OARs). To evaluate the effects of these techniques on dose inhomogeneity, we defined the PTV Dose Improvement (PDI) index, which was derived from a PTV volume between 97-103% of the differential DVHs. In addition, we compared the average monitor units (MUs) for each technique. The average PDI index with FIF is 76.4%, while the PDI indices for other treatments were 65.8, 41.8 and 50.9% for EC, EW and HW, respectively. This study demonstrated an improved performance using the FIF technique compared with the conventional HW/EW system, as well as a new modality for EC. We demonstrated that FIF is a very useful technique for improving PTV conformity, while protecting the OARs from breast tangential irradiation.

Entities:  

Mesh:

Year:  2008        PMID: 18216025     DOI: 10.1093/jjco/hym167

Source DB:  PubMed          Journal:  Jpn J Clin Oncol        ISSN: 0368-2811            Impact factor:   3.019


  17 in total

1.  Dosimetric comparison of the field-in-field technique and tangential wedged beams for breast irradiation.

Authors:  Cem Onal; Aydan Sonmez; Gungor Arslan; Ezgi Oymak; Ayse Kotek; Esma Efe; Serhat Sonmez; Yemliha Dolek
Journal:  Jpn J Radiol       Date:  2011-12-21       Impact factor: 2.374

2.  Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer.

Authors:  Tülay Ercan; Sefik Iğdem; Gül Alço; Funda Zengin; Selin Atilla; Maktav Dinçer; Sait Okkan
Journal:  Jpn J Radiol       Date:  2010-05-29       Impact factor: 2.374

3.  Usefulness of the dual energy field-in-field technique in breast tangential radiotherapy.

Authors:  Hidekazu Tanaka; Yuichi Kajiura; Masashi Kitahara; Katsuya Matsuyama; Masaya Kawaguchi; Takahiro Yamaguchi; Sunaho Okada; Masayuki Kanematsu
Journal:  Radiol Med       Date:  2015-12-11       Impact factor: 3.469

4.  Dosimetric evaluation of whole breast radiotherapy using field-in-field technique in early-stage breast cancer.

Authors:  Masahiro Sasaoka; Tomoyuki Futami
Journal:  Int J Clin Oncol       Date:  2011-01-14       Impact factor: 3.402

5.  Treatment planning study of Volumetric Modulated Arc Therapy and three dimensional field-in-field techniques for left chest-wall cancers with regional lymph nodes.

Authors:  Heping Xu; Gillian Hatcher
Journal:  Rep Pract Oncol Radiother       Date:  2016-08-24

6.  Comparison of Different Techniques in Breast Cancer Radiotherapy Planning.

Authors:  F Gülşen Kara; Ayfer Haydaroğlu; Hakan Eren; Gül Kitapçıoğlu
Journal:  J Breast Health       Date:  2014-04-01

7.  Secondary cancer risk after whole-breast radiation therapy: field-in-field versus intensity modulated radiation therapy versus volumetric modulated arc therapy.

Authors:  Emel Haciislamoglu; Yunus Cinar; Fatih Gurcan; Emine Canyilmaz; Gorkem Gungor; Adnan Yoney
Journal:  Br J Radiol       Date:  2019-07-22       Impact factor: 3.039

8.  The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques.

Authors:  Tomohisa Furuya; Satoru Sugimoto; Chie Kurokawa; Shuichi Ozawa; Kumiko Karasawa; Keisuke Sasai
Journal:  J Radiat Res       Date:  2012-08-01       Impact factor: 2.724

9.  Evaluation of the field-in-field technique with lung blocks for breast tangential radiotherapy.

Authors:  Hidekazu Tanaka; Shinya Hayashi; Yuichi Kajiura; Masashi Kitahara; Katsuya Matsuyama; Masayuki Kanematsu; Hiroaki Hoshi
Journal:  Nagoya J Med Sci       Date:  2015-08       Impact factor: 1.131

10.  Optimizing of the tangential technique and supraclavicular fields in 3 dimensional conformal radiation therapy for breast cancer.

Authors:  Keyvan Jabbari; Nazli Azarmahd; Shadi Babazade; Alireza Amouheidari
Journal:  J Med Signals Sens       Date:  2013-04
View more