Literature DB >> 18215394

Effects of different stent designs on local hemodynamics in stented arteries.

Rossella Balossino1, Francesca Gervaso, Francesco Migliavacca, Gabriele Dubini.   

Abstract

Following the deployment of a coronary stent and disruption of an atheromatous plaque, the deformation of the arterial wall and the presence of the stent struts create a new fluid dynamic field, which can cause an abnormal biological response. In this study 3D computational models were used to analyze the fluid dynamic disturbances induced by the placement of a stent inside a coronary artery. Stents models were first expanded against a simplified arterial plaque, with a solid mechanics analysis, and then subjected to a fluid flow simulation under pulsatile physiological conditions. Spatial and temporal distribution of arterial wall shear stress (WSS) was investigated after the expansion of stents of different designs and different strut thicknesses. Common oscillatory WSS behavior was detected in all stent models. Comparing stent and vessel wall surfaces, maximum WSS values (in the order of 1Pa) were located on the stent surface area. WSS spatial distribution on the vascular wall surface showed decreasing values from the center of the vessel wall portion delimited by the stent struts to the wall regions close to the struts. The hemodynamic effects induced by two different thickness values for the same stent design were investigated, too, and a reduced extension of low WSS region (<0.5Pa) was observed for the model with a thicker strut.

Mesh:

Year:  2008        PMID: 18215394     DOI: 10.1016/j.jbiomech.2007.12.005

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  10 in total

1.  Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived reconstructions.

Authors:  Christos V Bourantas; Michail I Papafaklis; Lampros Lakkas; Antonis Sakellarios; Yoshinobu Onuma; Yao-Jun Zhang; Takashi Muramatsu; Roberto Diletti; Paschalis Bizopoulos; Fanis Kalatzis; Katerina K Naka; Dimitrios I Fotiadis; Jin Wang; Hector M Garcia Garcia; Takeshi Kimura; Lampros K Michalis; Patrick W Serruys
Journal:  Int J Cardiovasc Imaging       Date:  2014-01-24       Impact factor: 2.357

2.  Computational fluid dynamic simulations of image-based stented coronary bifurcation models.

Authors:  Claudio Chiastra; Stefano Morlacchi; Diego Gallo; Umberto Morbiducci; Rubén Cárdenes; Ignacio Larrabide; Francesco Migliavacca
Journal:  J R Soc Interface       Date:  2013-05-15       Impact factor: 4.118

3.  Numerical simulation on the effects of drug-eluting stents with different bending angles on hemodynamics and drug distribution.

Authors:  Yu Chen; Yan Xiong; Wentao Jiang; Man Sang Wong; Fei Yan; Qingyuan Wang; Yubo Fan
Journal:  Med Biol Eng Comput       Date:  2016-04-05       Impact factor: 2.602

4.  Macro- and microscale variables regulate stent haemodynamics, fibrin deposition and thrombomodulin expression.

Authors:  Juan M Jiménez; Varesh Prasad; Michael D Yu; Christopher P Kampmeyer; Abdul-Hadi Kaakour; Pei-Jiang Wang; Sean F Maloney; Nathan Wright; Ian Johnston; Yi-Zhou Jiang; Peter F Davies
Journal:  J R Soc Interface       Date:  2014-02-19       Impact factor: 4.118

5.  Comparison of near-wall hemodynamic parameters in stented artery models.

Authors:  Nandini Duraiswamy; Richard T Schoephoerster; James E Moore
Journal:  J Biomech Eng       Date:  2009-06       Impact factor: 2.097

6.  Evaluation of the effect of stent strut profile on shear stress distribution using statistical moments.

Authors:  Juan Mejia; Bilal Ruzzeh; Rosaire Mongrain; Richard Leask; Olivier F Bertrand
Journal:  Biomed Eng Online       Date:  2009-04-30       Impact factor: 2.819

7.  Combined Effects of Flow Diverting Strategies and Parent Artery Curvature on Aneurysmal Hemodynamics: A CFD Study.

Authors:  Jinyu Xu; Zhichen Wu; Ying Yu; Nan Lv; Shengzhang Wang; Christof Karmonik; Jian-Min Liu; Qinghai Huang
Journal:  PLoS One       Date:  2015-09-23       Impact factor: 3.240

8.  Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design Considerations.

Authors:  Susann Beier; John Ormiston; Mark Webster; John Cater; Stuart Norris; Pau Medrano-Gracia; Alistair Young; Brett Cowan
Journal:  Ann Biomed Eng       Date:  2015-07-16       Impact factor: 3.934

9.  Hemodynamic Impact of Stenting on Carotid Bifurcation: A Potential Role of the Stented Segment and External Carotid Artery.

Authors:  Zhenmin Fan; Xiao Liu; Yingying Zhang; Nan Zhang; Xia Ye; Xiaoyan Deng
Journal:  Comput Math Methods Med       Date:  2021-11-26       Impact factor: 2.238

10.  Structural and Hemodynamic Analyses of Different Stent Structures in Curved and Stenotic Coronary Artery.

Authors:  Lingling Wei; Hwa Liang Leo; Qiang Chen; Zhiyong Li
Journal:  Front Bioeng Biotechnol       Date:  2019-12-06
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.