Devices for cardiac immunoassay are widely available at point of care settings. The lateral flow method is the most popular solution for ease of use. But its major shortcomings, poor assay precision, and low analytical sensitivity may lead to false negative results. Therefore, confirmatory testing by a routine lab analyzer sometimes is necessary. In the current study, we evaluated the cardiac assays troponin I, MB isoenzyme of creatine kinase, myoglobin, and N-terminal pro brain natriuretic peptide on a chemiluminescent enzyme immunoassay analyzer, PATHFAST. All of the assays demonstrated correlation coefficients higher than 0.97 against the predicate devices along with good total precision (coefficients of variation <10%), and the troponin I assay showed analytical sensitivity in conformance with the guidelines of European Society of Cardiology/American College of Cardiology and National Academy of Clinical Biochemistry. We concluded that the system was rapid and easy to use without compromising analytical performance.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18211813     DOI: 10.1016/j.ab.2007.12.030

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  14 in total

1.  Expression of CD64 on neutrophils can be used to predict the severity of bloodstream infection before broad range 16S rRNA PCR.

Authors:  David Stubljar; Miha Skvarc
Journal:  Folia Microbiol (Praha)       Date:  2014-09-26       Impact factor: 2.099

Review 2.  Emerging infection and sepsis biomarkers: will they change current therapies?

Authors:  Lauren Jacobs; Hector R Wong
Journal:  Expert Rev Anti Infect Ther       Date:  2016-08-17       Impact factor: 5.091

3.  Diagnostic and prognostic value of sCD14-ST--presepsin for patients admitted to hospital intensive care unit (ICU).

Authors:  Matej Godnic; David Stubljar; David Stubjar; Miha Skvarc; Tomislav Jukic
Journal:  Wien Klin Wochenschr       Date:  2015-04-09       Impact factor: 1.704

Review 4.  Point-of-care diagnostics for infectious diseases: From methods to devices.

Authors:  Chao Wang; Mei Liu; Zhifei Wang; Song Li; Yan Deng; Nongyue He
Journal:  Nano Today       Date:  2021-02-06       Impact factor: 20.722

5.  Diagnostic accuracy of presepsin (sCD14-ST) for prediction of bacterial infection in cerebrospinal fluid samples from children with suspected bacterial meningitis or ventriculitis.

Authors:  David Stubljar; Andreja Natasa Kopitar; Mojca Groselj-Grenc; Kristina Suhadolc; Teja Fabjan; Miha Skvarc
Journal:  J Clin Microbiol       Date:  2015-02-04       Impact factor: 5.948

6.  Clinical impact of kidney function on presepsin levels.

Authors:  Takanobu Nagata; Yoshinari Yasuda; Masahiko Ando; Tomoko Abe; Takayuki Katsuno; Sawako Kato; Naotake Tsuboi; Seiichi Matsuo; Shoichi Maruyama
Journal:  PLoS One       Date:  2015-06-01       Impact factor: 3.240

7.  The accuracy of presepsin (sCD14-ST) for the diagnosis of sepsis in adults: a meta-analysis.

Authors:  Xin Zhang; Dan Liu; You-Ning Liu; Rui Wang; Li-Xin Xie
Journal:  Crit Care       Date:  2015-09-11       Impact factor: 9.097

8.  New diagnostic strategy for sepsis-induced disseminated intravascular coagulation: a prospective single-center observational study.

Authors:  Hiroyasu Ishikura; Takeshi Nishida; Akira Murai; Yoshihiko Nakamura; Yuhei Irie; Junichi Tanaka; Takehiro Umemura
Journal:  Crit Care       Date:  2014-01-20       Impact factor: 9.097

9.  Chemiluminometric Immunosensor for High-Sensitivity Cardiac Troponin I Employing a Polymerized Enzyme Conjugate as a Tracer.

Authors:  Guei-Sam Lim; Sung-Min Seo; Sung-Ho Paek; Seung-Wan Kim; Jin-Woo Jeon; Dong-Hyung Kim; Il-Hoon Cho; Se-Hwan Paek
Journal:  Sci Rep       Date:  2015-10-07       Impact factor: 4.379

10.  Usefulness of presepsin in the diagnosis of sepsis in patients with or without acute kidney injury.

Authors:  Yoshihiko Nakamura; Hiroyasu Ishikura; Takeshi Nishida; Yasumasa Kawano; Rie Yuge; Reiko Ichiki; Akira Murai
Journal:  BMC Anesthesiol       Date:  2014-10-04       Impact factor: 2.217

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.