Literature DB >> 18209573

The acute effect of an echo-contrast agent on right ventricular dimensions and contractility in pigs.

Dimitris Bramos1, Nikolaos Tsirikos, Giorgos Kottis, Constantinos Pamboucas, Vichy Kostopoulou, Crysanthi Trika, Ignatios Ikonomidis, Savvas Toumanidis.   

Abstract

BACKGROUND: : The aim of the present study was to examine the effect of the second-generation ultrasound contrast agent (2nd GUCA) SonoVue on right ventricular (RV) dimensions and contractility and to investigate whether a dose-related interaction exists between the contrast agent and RV function.
METHODS: : Twenty-eight pigs were randomly assigned to 3 groups for intravenous administration: a low-dose group (0.5 cc of SonoVue), a high-dose group (1 cc of SonoVue), and a control group (2 cc of normal saline). RV end-diastolic (EDD) and end-systolic dimension (ESD) and pulmonary pressure (PP) were measured, and the fractional shortening (FS%) was calculated before the administration of SonoVue or normal saline and after the return of the RV-EDD or PP to the baseline value. The time to reach maximal RV-EDD or PP value and the time until the return of RV-EDD or PP to the baseline value were also measured.
RESULTS: : Contrast agent infusion was followed by an acute transient increase of RV-EDD, RV-ESD, FS, and PP in both the low-dose and high-dose groups, but the increase was greater in the high-dose group. FS and PP did not change significantly in the control group. A dose-dependent delay in the time from baseline to maximum RV-EDD and PP was detected in the high-dose group (P < 0.001 for both) as well as a delay in the return from maximum to the baseline values (P < 0.001 for both).
CONCLUSIONS: : Administration of the 2nd GUCA SonoVue is associated with an acute, transient, dose-dependent RV dilatation and an increase in pulmonary pressure with a consequent impact on RV contractility.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18209573     DOI: 10.1097/FJC.0b013e31815c660c

Source DB:  PubMed          Journal:  J Cardiovasc Pharmacol        ISSN: 0160-2446            Impact factor:   3.105


  3 in total

1.  Contrast-enhanced diagnostic ultrasound causes renal tissue damage in a porcine model.

Authors:  Douglas L Miller; Chunyan Dou; Roger C Wiggins
Journal:  J Ultrasound Med       Date:  2010-10       Impact factor: 2.153

2.  An Intracardiac Soft Robotic Device for Augmentation of Blood Ejection from the Failing Right Ventricle.

Authors:  Markus A Horvath; Isaac Wamala; Eric Rytkin; Elizabeth Doyle; Christopher J Payne; Thomas Thalhofer; Ignacio Berra; Anna Solovyeva; Mossab Saeed; Sara Hendren; Ellen T Roche; Pedro J Del Nido; Conor J Walsh; Nikolay V Vasilyev
Journal:  Ann Biomed Eng       Date:  2017-05-16       Impact factor: 3.934

3.  Contrast-enhanced ultrasound evaluation of renal microcirculation in sheep.

Authors:  Antoine G Schneider; Paolo Calzavacca; Anthony Schelleman; Tim Huynh; Michael Bailey; Clive May; Rinaldo Bellomo
Journal:  Intensive Care Med Exp       Date:  2014-11-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.