Dialyzer reuse impact on dialyzer efficiency, patient morbidity and mortality and cost effectiveness.

A H Mitwalli1, J Abed, N Tarif, A Alam, J S Al-Wakeel, H Abu-Aisha, N Memon, F Sulaimani, B Ternate, M O Mensah.   

Abstract

Since the introduction of dialyzer reuse more than three decades ago, several studies have reported its safety, efficacy and cost effectiveness. Reuse of hemodialyzer was prospectively studied in ten chronic hemodialysis (HD) patients recruited from the renal unit, the King Khalid University Hospital, Riyadh, Saudi Arabia, for three months. During the study period, 66 dialyzers were used for 408 sessions of HD, with a mean reuse of 6.2 +/- 5.3 episodes per dialyser, the mean of maximum reuse episodes being 13.7 +/- 8.0. The urea reduction ratio was maintained between 73 +/- 5% at baseline to 71.2 +/- 9.03% (p=0.53) at the maximum reuse. Similarly phosphate reduction with each HD session was maintained; mean decrease in phosphate levels was 0.67 mmol/L. Significant increase in heparin requirement was noted; however, the risk of bleeding was not increased. Hematocrit levels increased from 30.4 +/- 4.1% to 33.2 +/- 3.6% at the end of the study (p=0.6). Albumin leak in dialysate decreased with each reuse; baseline 8.27 +/- 7.93 mg/L to 2.8 +/- 0.4 mg/L at maximum reuse (p=0.04). Serum albumin levels remained stable. No short-term adverse effects on patients' morbidity and mortality were noted. Total cost savings of 53% was achieved with the reuse of dialyzers, excluding capital equipment used for preparation for reuse. In conclusion, dialyzer reuse seems to be safe and may provide an economical and efficient dialysis. Studies involving larger number of patients is required to validate this observation.

Entities:  

Year:  2001        PMID: 18209377

Source DB:  PubMed          Journal:  Saudi J Kidney Dis Transpl        ISSN: 1319-2442


  3 in total

1.  Correlates and variance decomposition analysis of heparin dosing for maintenance hemodialysis in older US patients.

Authors:  Jenny I Shen; Maria E Montez-Rath; Aya A Mitani; Kevin F Erickson; Wolfgang C Winkelmayer
Journal:  Pharmacoepidemiol Drug Saf       Date:  2014-02-18       Impact factor: 2.890

2.  State of health economic evaluation research in Saudi Arabia: a review.

Authors:  Sinaa A Al-Aqeel
Journal:  Clinicoecon Outcomes Res       Date:  2012-07-05

3.  Effects of dialyzer reuse on dialysis adequacy, anemia control, erythropoieting-stimulating agents use and phosphate level.

Authors:  Jolanta Malyszko; Andrzej Milkowski; Ewa Benedyk-Lorens; Teresa Dryl-Rydzynska
Journal:  Arch Med Sci       Date:  2016-02-02       Impact factor: 3.318