Bivariate evaluation of cylinder implant diameter and length: a three-dimensional finite element analysis.

Liang Kong1, Yingying Sun, Kaijin Hu, Dehua Li, Rui Hou, Jin Yang, Baolin Liu.   

Abstract

PURPOSE: To evaluate continuous and simultaneous variations of implant diameter and length for an experimental cylinder implant.
MATERIALS AND METHODS: A finite element model of a mandible segment with implant was created. The range of implant diameter (D) was set from 2.5 to 5.0 mm, and that of implant length (L) from 6.0 to 16.0 mm. The maximum Von Mises stresses in the mandible were evaluated, and the sensitivity of the stresses in the mandible to the variables was also evaluated.
RESULTS: Under axial load, the maximum von Mises stresses in cortical and cancellous bones decreased by 73.3% and 69.4%, respectively, with D and L increasing. Under buccolingual load, those decreased 83.8% and 79.2%, respectively. When D exceeded 3.9 mm and L exceeded 10.0 mm, the tangent slope rate of the maximum von Mises stress response curve ranged from -1 to 0. The variation of the maximum von Mises stresses in the mandible was more sensitive to D than to L.
CONCLUSIONS: Buccolingual force is apt to be influenced by the two implant parameters; implant diameter and length favor stress distribution in cortical bone and cancellous bone, respectively. Implant diameter exceeding 3.9 mm and implant length exceeding 10.0 mm are the optimal choice for type B/2 bone in a cylinder implant. The implant diameter is more important than length in reducing bone stress.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18205741     DOI: 10.1111/j.1532-849X.2007.00286.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  5 in total

1.  Optimization Analysis of Two-Factor Continuous Variable between Thread Depth and Pitch of Microimplant under Toque Force.

Authors:  Yushan Ye; Jiuyang Jiao; Song Fan; Jieying He; Yamei Wang; Qinghe Yao; Wei Wang; Jinsong Li; Shaohai Chang
Journal:  Comput Math Methods Med       Date:  2022-06-20       Impact factor: 2.809

2.  Influence of Inter-Radicular Septal Bone Quantity in Primary Stability of Immediate Molar Implants with Different Length and Diameter Placed in Mandibular Region. A Cone-Beam Computed Tomography-Based Simulated Implant Study.

Authors:  Arshad Jamal Sayed; Safia Shoeb Shaikh; Shoeb Yakub Shaikh; Mohammed Abid Hussain; Sabahat Ullah Khan Tareen; Vaibhav Awinashe
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05

3.  The influence of length of implant on primary stability: An in vitro study using resonance frequency analysis.

Authors:  Anwar B Bataineh; Ala M Al-Dakes
Journal:  J Clin Exp Dent       Date:  2017-01-01

4.  Implant survival and patient satisfaction in completely edentulous patients with immediate placement of implants: a retrospective study.

Authors:  Hye-Sung Kim; Han-A Cho; Young Youn Kim; Hosung Shin
Journal:  BMC Oral Health       Date:  2018-12-18       Impact factor: 2.757

5.  Comparison of the Effect of Three Abutment-implant Connections on Stress Distribution at the Internal Surface of Dental Implants: A Finite Element Analysis.

Authors:  Saeed Raoofi; Maryam Khademi; Reza Amid; Mahdi Kadkhodazadeh; Mohammad Reza Movahhedi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2013-08-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.