Literature DB >> 18203541

Hemodynamic monitoring using PiCCO system in a 10 months old infant suffering from serious burn injury.

J Koppl1, D Karovic, B Podhoransky, D Csomor, P Gasparec, T Sagat, H Trimmel.   

Abstract

In this study, authors present a case report of a 10 months old patient with burn injuries involving 20.5 % body surface area, grades 2a and 2b. According to the continuous monitoring of hemodynamic parameters by PiCCO (Pulsion Medical Systems, Munich, Germany), fluid therapy was successfully managed. Despite of an increasing EVLWI (extravascular lung water index) it was possible to preserve the child from lung edema and subsequent artificial lung ventilation by the early targeted therapeutic interventions. Moreover, the study analyzes the possibilities and indications of less invasive hemodynamic monitoring supplied by PiCCO in children (Tab. 2, Fig. 3, Ref. 7). Full Text (Free, PDF) www.bmj.sk.

Entities:  

Mesh:

Year:  2007        PMID: 18203541

Source DB:  PubMed          Journal:  Bratisl Lek Listy        ISSN: 0006-9248            Impact factor:   1.278


  1 in total

1.  Validation of cardiac output measurement by ultrasound dilution technique with pulmonary artery thermodilution in a pediatric animal model.

Authors:  Edward Darling; Naveen Thuramalla; Bruce Searles
Journal:  Pediatr Cardiol       Date:  2011-02-27       Impact factor: 1.655