Literature DB >> 18201886

Sensitive and rapid detection of 2,4-dicholorophenoxyacetic acid in water samples by using evanescent wave all-fiber immunosensor.

F Long1, H C Shi, M He, A N Zhu.   

Abstract

Sensitive and rapid detection of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) was achieved with a newly developed evanescent wave all-fiber immunosensor (EWAI). A reusable functional sensing surface of the immunosensor is prepared by covalent binding of 2,4-D-bovine serum albumin (2,4-D-BSA) conjugate to a self-assembled alkanethiol monolayer formed onto the fiber optic probe through heterobifunctional reagent. The quantification of free 2,4-D in samples was based on indirect competitive immunoreaction principle. Under optimum conditions, calibration curve obtained for 2,4-D had detection limits of 0.07 microg L(-1), the 50% inhibition concentration (IC(50)) was 3.93+/-0.03 microg L(-1) and the quantitative detection range was 0.22-69.5 microg L(-1). The antibodies binding on the sensor surface could be removed simply by the flow of a pepsin solution (pH 1.9), facilitating reuse of the same probe. The regeneration of the sensor surface allowed the performance of more than 100 assay cycles without significant loss of reactivity. The antibody showed negligible cross-reactivity against a few compounds structurally similar to 2,4-D. The immunosensor developed was successfully applied to the monitoring of 2,4-D in spiked water samples without significant effect of the matrix. The proposed portable immunosensor is promising for real-time on-site analysis of small molecules of environmental interest.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18201886     DOI: 10.1016/j.bios.2007.12.004

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  An imprinted polymeric matrix containing DNA for electrochemical sensing of 2,4-dichlorophenoxyacetic acid.

Authors:  Fatemeh Azadmehr; Kobra Zarei
Journal:  Mikrochim Acta       Date:  2019-11-19       Impact factor: 5.833

2.  Adsorption Kinetics of Single-Stranded DNA on Functional Silica Surfaces and Its Influence Factors: An Evanescent-Wave Biosensor Study.

Authors:  Jun Wu; Hongliang Wang; Anna Zhu; Feng Long
Journal:  ACS Omega       Date:  2018-05-25

Review 3.  Fluorescence based fiber optic and planar waveguide biosensors. A review.

Authors:  Elena Benito-Peña; Mayra Granda Valdés; Bettina Glahn-Martínez; Maria C Moreno-Bondi
Journal:  Anal Chim Acta       Date:  2016-09-13       Impact factor: 6.558

4.  Matrix Effects on the Microcystin-LR Fluorescent Immunoassay Based on Optical Biosensor.

Authors:  Feng Long; An-Na Zhu; Jian-Wu Sheng; Miao He; Han-Chang Shi
Journal:  Sensors (Basel)       Date:  2009-04-23       Impact factor: 3.576

Review 5.  Recent advances in optical biosensors for environmental monitoring and early warning.

Authors:  Feng Long; Anna Zhu; Hanchang Shi
Journal:  Sensors (Basel)       Date:  2013-10-15       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.