Literature DB >> 18201282

Comparison of methods to identify significant proteinuria in pregnancy in the outpatient setting.

P M Kyle1, J N Fielder, B Pullar, L J Horwood, M P Moore.   

Abstract

The efficacy of the albumin/creatinine ratio (ACR) measurement in detection of significant proteinuria when performed in a high-risk antenatal clinic was compared with automated dipstick, protein/creatinine ratio (PCR), and 24-hour urine protein measurements. Both the ACR (DCA 2000) and PCR were strongly predictive for the presence or absence of significant proteinuria, with positive likelihood ratios (LRs) of 27.4 and 31.6 and negative LRs of 0.0 and 0.1, respectively. Both the ACR (DCA 2000) and PCR are effective tests for both identifying and excluding significant proteinuria in the outpatient setting. The ACR (DCA 2000) has the advantage of providing an immediate result.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18201282     DOI: 10.1111/j.1471-0528.2007.01621.x

Source DB:  PubMed          Journal:  BJOG        ISSN: 1470-0328            Impact factor:   6.531


  5 in total

1.  Analysis of Proteinuria Estimation Methods in Hypertensive Disorders of Pregnancy.

Authors:  Hanumant V Nipanal; Dilip Kumar Maurrya; S Susmitha; P N Ravindra
Journal:  J Obstet Gynaecol India       Date:  2017-11-23

Review 2.  Preeclampsia: Risk Factors, Diagnosis, Management, and the Cardiovascular Impact on the Offspring.

Authors:  Rachael Fox; Jamie Kitt; Paul Leeson; Christina Y L Aye; Adam J Lewandowski
Journal:  J Clin Med       Date:  2019-10-04       Impact factor: 4.241

3.  Investigation of the impact of urine handling procedures on interpretation of urinalysis findings and product safety in subjects treated with ezogabine.

Authors:  Neil Brickel; Sarah Derossett; Mauro Buraglio; Christopher Evans; Siôn Jones
Journal:  Ther Clin Risk Manag       Date:  2013-05-07       Impact factor: 2.423

4.  Quantifying proteinuria in hypertensive disorders of pregnancy.

Authors:  Sapna V Amin; Sireesha Illipilla; Shripad Hebbar; Lavanya Rai; Pratap Kumar; Muralidhar V Pai
Journal:  Int J Hypertens       Date:  2014-09-16       Impact factor: 2.420

5.  Diagnostic accuracy of spot albumin creatinine ratio and its association with fetomaternal outcome in preeclampsia and eclampsia.

Authors:  Rekha Sachan; Munna Lal Patel; Pushpalata Sachan; Radhey Shyam; Pratima Verma; Soniya Dheeman
Journal:  Niger Med J       Date:  2017 Mar-Apr
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.