Literature DB >> 18199440

Improved liquid chromatographic method with pulsed electrochemical detection for the analysis of gentamicin.

Vicky Manyanga1, Katjusa Kreft, Blaz Divjak, Jos Hoogmartens, Erwin Adams.   

Abstract

The official method for the determination of the composition and related substances of gentamicin prescribed by the European Pharmacopoeia (Ph. Eur.) is liquid chromatography combined with pulsed electrochemical detection (LC-PED). However, this method utilizes a polymer stationary phase which shows rather low efficiency towards the separation of the main gentamicin components. Moreover, the mobile phase contains a lot of non volatile salts: sodium sulphate and sodium octanesulphonate. Following a comparative study, the most performant LC-PED method has been evaluated and validated using a reversed phase C18 column (C18, 250 x 4.6mm ID, 110 A, 5 microm) kept at 35 degrees C with a mobile phase containing volatile ion pairing agents: trifluoroacetic acetic acid (TFA) and pentafluoropropionic acid (PFPA). In addition to the selectivity of the main gentamicin components and its related substances, the method is repeatable, linear and proves to be robust. It is also applicable to a wider number of C18 columns.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18199440     DOI: 10.1016/j.chroma.2007.12.041

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  Determination of Gentamicin Sulphate Composition and Related Substances in Pharmaceutical Preparations by LC with Charged Aerosol Detection.

Authors:  Karolina Stypulkowska; Agata Blazewicz; Zbigniew Fijalek; Katarzyna Sarna
Journal:  Chromatographia       Date:  2010-10-01       Impact factor: 2.044

2.  LC-MS/MS method for simultaneous quantification of dexamethasone and tobramycin in rabbit ocular biofluids.

Authors:  Tuo Meng; Leon Kosmider; Guihong Chai; Aji Alex Moothedathu Raynold; Adam C Pearcy; Bin Qin; Yan Wang; Xiuling Lu; Matthew S Halquist; Qingguo Xu
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2021-03-01       Impact factor: 3.205

3.  Development of a multicommutated flow system with chemiluminometric detection for quantification of gentamicin in pharmaceuticals.

Authors:  Lúcia H M L M Santos; A N Araújo; Boaventura Reis; M C B S M Montenegro
Journal:  J Autom Methods Manag Chem       Date:  2010-10-13

4.  The impact of storage conditions upon gentamicin coated antimicrobial implants.

Authors:  Nicholas D Mullins; Benjamin J Deadman; Humphrey A Moynihan; Florence O McCarthy; Simon E Lawrence; Jonathan Thompson; Anita R Maguire
Journal:  J Pharm Anal       Date:  2016-05-26

5.  ELISA-based detection of gentamicin and vancomycin in protein-containing samples.

Authors:  Jim C E Odekerken; Dorien M W Logister; Loubna Assabre; Jacobus J C Arts; Geert H I M Walenkamp; Tim J M Welting
Journal:  Springerplus       Date:  2015-10-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.