Literature DB >> 18198921

Four-dimensional stereotactic radiotherapy for early stage non-small cell lung cancer: a comparative planning study.

J-B Prevost1, P Voet, M Hoogeman, J Praag, P Levendag, J J Nuyttens.   

Abstract

In this study we sought to assess the potential of the respiratory tumor tracking system of the CyberKnife to administer 3 fractions of 15 Gy in the treatment of early stage non-small cell lung cancer (NSCLC). The CyberKnife plans were compared to those developed for 3-D conformal radiotherapy (3-D CRT) administering 20 fractions of 3 Gy based on a slow CT. Ten patients with stage I NSCLC, who were previously treated with 3-D CRT, were re-planned with the CyberKnife treatment planning system. In the 3-D CRT plan, the planning target volume (PTV) included the gross tumor volume (GTV)(slow) and a 15-mm margin, whereas in the CyberKnife plan the margin was 8 mm. The physical doses from both treatment plans were converted to normalized total doses (NTD) using the linear quadratic model with an alpha/beta(tumor) of 10 Gy and alpha/beta(organs at risk (OAR)) of 3 Gy. The average minimal and mean doses administered to the PTV with the CyberKnife and 3-D CRT were 93 and 115.8 Gy and 61 and 66 Gy, respectively (p<0.0001). The mean V(20) of the CyberKnife and 3-D CRT plans were 8.2% and 6.8%, respectively (p=0.124). Both plans complied with the OAR constraints. In conclusion, 4-dimensional stereotactic radiotherapy can increase the minimal and mean biological dose with 51% and 75%, in comparison with 3-D CRT without significantly increasing the V(20), respectively.

Entities:  

Mesh:

Year:  2008        PMID: 18198921     DOI: 10.1177/153303460800700103

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  8 in total

1.  Advantages of CyberKnife for inoperable stage I peripheral non-small-cell lung cancer compared to three-dimensional conformal radiotherapy.

Authors:  An-Na Tong; Peng Yan; Guang-Hui Yuan; Xiao-Yan Lv; Hai Gong; Hui Zhao; Yan-Ming Wang
Journal:  Mol Clin Oncol       Date:  2014-12-10

2.  The linear-quadratic model is an appropriate methodology for determining isoeffective doses at large doses per fraction.

Authors:  David J Brenner
Journal:  Semin Radiat Oncol       Date:  2008-10       Impact factor: 5.934

3.  Stereotactic body radiotherapy for centrally located early-stage non-small cell lung cancer or lung metastases from the RSSearch(®) patient registry.

Authors:  Joanne N Davis; Clinton Medbery; Sanjeev Sharma; John Pablo; Frank Kimsey; David Perry; Alexander Muacevic; Anand Mahadevan
Journal:  Radiat Oncol       Date:  2015-05-15       Impact factor: 3.481

Review 4.  Complications from Stereotactic Body Radiotherapy for Lung Cancer.

Authors:  Kylie H Kang; Christian C Okoye; Ravi B Patel; Shankar Siva; Tithi Biswas; Rodney J Ellis; Min Yao; Mitchell Machtay; Simon S Lo
Journal:  Cancers (Basel)       Date:  2015-06-15       Impact factor: 6.639

5.  A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac-based systems.

Authors:  Chuxiong Ding; Cheng-Hui Chang; Joshua Haslam; Robert Timmerman; Timothy Solberg
Journal:  J Appl Clin Med Phys       Date:  2010-06-29       Impact factor: 2.102

6.  Dosimetric evaluation of four-dimensional dose distributions of CyberKnife and volumetric-modulated arc radiotherapy in stereotactic body lung radiotherapy.

Authors:  Mark K H Chan; Dora L W Kwong; Gilbert M L Law; Eric Tam; Anthony Tong; Venus Lee; Sherry C Y Ng
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

7.  [Preliminary effect of Cyberknife radiosurgery in the treatment of 31 patients with advanced non-small cell lung cancer].

Authors:  Yanling Lv; Zhen Wang; Xixu Zhu; Zetian Shen; Dongmei Yuan; Xiaohui Miao; Yi Shi; Yong Song
Journal:  Zhongguo Fei Ai Za Zhi       Date:  2011-04

8.  Treating adrenal tumors in 26 patients with CyberKnife: a mono-institutional experience.

Authors:  Jing Li; Zhaorong Shi; Zhen Wang; Zhibing Liu; Xinhu Wu; Zetian Shen; Bing Li; Yong Song; Xixu Zhu
Journal:  PLoS One       Date:  2013-11-20       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.