Literature DB >> 18198846

Covalent virus layer for mass-based biosensing.

Li-Mei C Yang1, Juan E Diaz, Theresa M McIntire, Gregory A Weiss, Reginald M Penner.   

Abstract

M13 virus particles were covalently attached to a planar gold-coated quartz crystal microbalance (QCM) through reaction with a self-assembled monolayer of N-hydroxysuccinimide thioctic ester, followed by incorporation of the blocking agent bovine serum albumin. This immobilization chemistry produced a phage multilayer having a coverage equivalent to approximately 6.5 close-packed monolayers of the virus. The properties of this "covalent virus surface" or CVS for the mass-based detection of a 148.2 kDa antibody were then evaluated in a phosphate buffer using a flow injection analysis system. The mass of the CVS increased with exposure to an antibody (p-Ab) known to bind the phage particles with high affinity. Bound p-Ab was removed by washing with 0.5 M HCl thereby regenerating the sensor surface. A calibration plot for p-Ab binding was constructed by repetitively exposing the surface to p-Ab at concentrations between 6.6 and 200 nM and HCl rinsing after each exposure. The mass-concentration relationship was linear with a sensitivity of 0.018 microg/(cm2 nM) and a limit of detection of 7 nM or 1.3 pmol. The CVS could be saturated with high doses of p-Ab enabling the determination that an average of approximately 140 binding sites are available per M13 phage particle. Exposure of the CVS to a second, nonbinding antibody (n-Ab) did not cause a measurable mass change. These results demonstrate that the covalent virus layer is a rugged, selective, and sensitive means for carrying out mass-based biodetection.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18198846     DOI: 10.1021/ac071470f

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  15 in total

Review 1.  Virus-based chemical and biological sensing.

Authors:  Chuanbin Mao; Aihua Liu; Binrui Cao
Journal:  Angew Chem Int Ed Engl       Date:  2009       Impact factor: 15.336

2.  Virus Bioresistor (VBR) for Detection of Bladder Cancer Marker DJ-1 in Urine at 10 pM in One Minute.

Authors:  Apurva Bhasin; Emily C Sanders; Joshua M Ziegler; Jeffrey S Briggs; Nicholas P Drago; Aisha M Attar; Alicia M Santos; Marie Y True; Alana F Ogata; Debora V Yoon; Sudipta Majumdar; Andrew J Wheat; Shae V Patterson; Gregory A Weiss; Reginald M Penner
Journal:  Anal Chem       Date:  2020-04-20       Impact factor: 6.986

3.  Portable and quantitative detection of protein biomarkers and small molecular toxins using antibodies and ubiquitous personal glucose meters.

Authors:  Yu Xiang; Yi Lu
Journal:  Anal Chem       Date:  2012-04-16       Impact factor: 6.986

4.  Virus-polymer hybrid nanowires tailored to detect prostate-specific membrane antigen.

Authors:  Jessica A Arter; Juan E Diaz; Keith C Donavan; Tom Yuan; Reginald M Penner; Gregory A Weiss
Journal:  Anal Chem       Date:  2012-03-07       Impact factor: 6.986

5.  Virus-poly(3,4-ethylenedioxythiophene) composite films for impedance-based biosensing.

Authors:  Keith C Donavan; Jessica A Arter; Rosa Pilolli; Nicola Cioffi; Gregory A Weiss; Reginald M Penner
Journal:  Anal Chem       Date:  2011-03-09       Impact factor: 6.986

Review 6.  Chemically Modifying Viruses for Diverse Applications.

Authors:  Kritika Mohan; Gregory A Weiss
Journal:  ACS Chem Biol       Date:  2016-03-21       Impact factor: 5.100

Review 7.  Molecular Sensing with Host Systems for Hyperpolarized 129Xe.

Authors:  Jabadurai Jayapaul; Leif Schröder
Journal:  Molecules       Date:  2020-10-11       Impact factor: 4.411

8.  Chemical and genetic wrappers for improved phage and RNA display.

Authors:  Jorge A Lamboy; Phillip Y Tam; Lucie S Lee; Pilgrim J Jackson; Sara K Avrantinis; Hye J Lee; Robert M Corn; Gregory A Weiss
Journal:  Chembiochem       Date:  2008-11-24       Impact factor: 3.164

9.  Real-time Recognition of Mycobacterium tuberculosis and Lipoarabinomannan using the Quartz Crystal Microbalance.

Authors:  Leslie A Hiatt; David E Cliffel
Journal:  Sens Actuators B Chem       Date:  2012-08-19       Impact factor: 7.460

10.  Biosensing with Virus Electrode Hybrids.

Authors:  Kritika Mohan; Reginald M Penner; Gregory A Weiss
Journal:  Curr Protoc Chem Biol       Date:  2015-06-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.