Literature DB >> 18196799

Adaptation of antenna profiles for control of MR guided hyperthermia (HT) in a hybrid MR-HT system.

Mirko Weihrauch1, Peter Wust, Martin Weiser, Jacek Nadobny, Steffen Eisenhardt, Volker Budach, Johanna Gellermann.   

Abstract

A combined numerical-experimental iterative procedure, based on the Gauss-Newton algorithm, has been developed for control of magnetic resonance (MR)-guided hyperthermia (HT) applications in a hybrid MR-HT system BSD 2000 3D-MRI. In this MR-HT system, composed of a 3-D HT applicator Sigma-Eye placed inside a tunnel-type MR tomograph Siemens MAGNETOM Symphony (1.5 T), the temperature rise due to the HT radiation can be measured on-line in three dimensions by use of the proton resonance frequency shift (PRFS) method. The basic idea of our iterative procedure is the improvement of the system's characterization by a step-by-step modification of the theoretical HT antenna profiles (electric fields radiated by single antennas). The adaptation of antenna profiles is efficient if the initial estimates are radiation fields calculated from a good a priori electromagnetic model. Throughout the iterative procedure, the calculated antenna fields (FDTD) are step-by-step modified by comparing the calculated and experimental data, the latter obtained using the PRFS method. The procedure has been experimentally tested on homogeneous and inhomogeneous phantoms. It is shown that only few comparison steps are necessary for obtaining a dramatic improvement of the general predictability and quality of the specific absorption rate (SAR) inside the MR-HT hybrid system.

Entities:  

Mesh:

Year:  2007        PMID: 18196799     DOI: 10.1118/1.2804617

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  Mathematical formulation and analysis of the nonlinear system reconstruction of the online image-guided adaptive control of hyperthermia.

Authors:  Kung-Shan Cheng; Mark W Dewhirst; Paul F Stauffer; Shiva Das
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  Improved hyperthermia treatment control using SAR/temperature simulation and PRFS magnetic resonance thermal imaging.

Authors:  Zhen Li; Martin Vogel; Paolo F Maccarini; Vadim Stakhursky; Brian J Soher; Oana I Craciunescu; Shiva Das; Omar A Arabe; Williams T Joines; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2010-11-11       Impact factor: 3.914

3.  Stable Microwave Radiometry System for Long Term Monitoring of Deep Tissue Temperature.

Authors:  Paul R Stauffer; Dario B Rodriques; Sara Salahi; Erdem Topsakal; Tiago R Oliveira; Aniruddh Prakash; Fabio D'Isidoro; Douglas Reudink; Brent W Snow; Paolo F Maccarini
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-02-26

4.  Mild hyperthermia with magnetic resonance-guided high-intensity focused ultrasound for applications in drug delivery.

Authors:  Ari Partanen; Pavel S Yarmolenko; Antti Viitala; Sunil Appanaboyina; Dieter Haemmerich; Ashish Ranjan; Genevieve Jacobs; David Woods; Julia Enholm; Bradford J Wood; Matthew R Dreher
Journal:  Int J Hyperthermia       Date:  2012       Impact factor: 3.914

5.  Effective learning strategies for real-time image-guided adaptive control of multiple-source hyperthermia applicators.

Authors:  Kung-Shan Cheng; Mark W Dewhirst; Paul R Stauffer; Shiva Das
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

6.  Reduction of peak acoustic pressure and shaping of heated region by use of multifoci sonications in MR-guided high-intensity focused ultrasound mediated mild hyperthermia.

Authors:  Ari Partanen; Matti Tillander; Pavel S Yarmolenko; Bradford J Wood; Matthew R Dreher; Max O Kohler
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

Review 7.  Heating technology for malignant tumors: a review.

Authors:  H Petra Kok; Erik N K Cressman; Wim Ceelen; Christopher L Brace; Robert Ivkov; Holger Grüll; Gail Ter Haar; Peter Wust; Johannes Crezee
Journal:  Int J Hyperthermia       Date:  2020       Impact factor: 3.914

8.  Real-time MRI-guided hyperthermia treatment using a fast adaptive algorithm.

Authors:  Vadim L Stakhursky; Omar Arabe; Kung-Shan Cheng; James Macfall; Paolo Maccarini; Oana Craciunescu; Mark Dewhirst; Paul Stauffer; Shiva K Das
Journal:  Phys Med Biol       Date:  2009-03-13       Impact factor: 3.609

Review 9.  Simulation techniques in hyperthermia treatment planning.

Authors:  Margarethus M Paulides; Paul R Stauffer; Esra Neufeld; Paolo F Maccarini; Adamos Kyriakou; Richard A M Canters; Chris J Diederich; Jurriaan F Bakker; Gerard C Van Rhoon
Journal:  Int J Hyperthermia       Date:  2013-05-14       Impact factor: 3.914

10.  The performance of a reduced-order adaptive controller when used in multi-antenna hyperthermia treatments with nonlinear temperature-dependent perfusion.

Authors:  Kung-Shan Cheng; Yu Yuan; Zhen Li; Paul R Stauffer; Paolo Maccarini; William T Joines; Mark W Dewhirst; Shiva K Das
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.