Literature DB >> 18196783

Monte Carlo investigation of breast intraoperative radiation therapy with metal attenuator plates.

A Martignano1, L Menegotti, A Valentini.   

Abstract

In intraoperative electron radiation therapy for breast cancer, attenuation plates are commonly used to protect organs at risk. These plates can be made of different materials, and the correct material (or combination of materials) has to be chosen in order to achieve the desired attenuation, while avoiding excessive backscattered radiation. The Monte Carlo method (BEAMnrcMP and DOSXYZnrcMP) has been used to characterize the electron beam generated by the setup (composed of a nondedicated linac and an applicator), and to simulate the percent depth dose (PDD) for plates of different materials. The beam has been characterized for nominal energies of 9 and 12 MeV. Several differently composed plates have been investigated: it was found, as expected, that the use of a plate presenting to the electron beam a high-Z material (i.e., lead) has to be avoided because of excessive backscatter (up to 52% compared to the PDD without plate). On the other hand, the use of a single low-Z material (i.e., aluminum) in the plate can lead to an insufficient attenuation of the beam. The two-layer plate (6 mm of Al plus 3 mm of Cu) used in S. Chiara Hospital has been found to attenuate the beam almost completely for both considered energies, causing negligible backscatter radiation. The spectrum at various depth and at the tissue-plate interface has also been investigated.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18196783     DOI: 10.1118/1.2805089

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Comparing the performance of some dedicated radioprotection disks in breast intraoperative electron radiotherapy: a Monte Carlo study.

Authors:  Hamid Reza Baghani; Mostafa Robatjazi; Seyed Rabi Mahdavi
Journal:  Radiat Environ Biophys       Date:  2020-04-06       Impact factor: 1.925

2.  In vivo dosimetry and shielding disk alignment verification by EBT3 GAFCHROMIC film in breast IOERT treatment.

Authors:  Mara Severgnini; Mario de Denaro; Marina Bortul; Cristiana Vidali; Aulo Beorchia
Journal:  J Appl Clin Med Phys       Date:  2014-01-08       Impact factor: 2.102

Review 3.  Present state and issues in IORT Physics.

Authors:  Frank W Hensley
Journal:  Radiat Oncol       Date:  2017-01-27       Impact factor: 3.481

4.  Dosimetric characteristics of electron beams produced by two mobile accelerators, Novac7 and Liac, for intraoperative radiation therapy through Monte Carlo simulation.

Authors:  Sergio Righi; Evis Karaj; Giuseppe Felici; Fabio Di Martino
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102

5.  Dose distribution changes with shielding disc misalignments and wrong orientations in breast IOERT: a Monte Carlo - GEANT4 and experimental study.

Authors:  Giorgio Russo; Carlo Casarino; Gaetano Arnetta; Giuliana Candiano; Alessandro Stefano; Filippo Alongi; Giovanni Borasi; Cristina Messa; Maria C Gilardi
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  5 in total