Literature DB >> 18195385

Blunt abdominal trauma: diagnostic performance of contrast-enhanced US in children--initial experience.

Massimo Valentino1, Carla Serra, Pietro Pavlica, Antonio Maria Morselli Labate, Mario Lima, Simonetta Baroncini, Libero Barozzi.   

Abstract

PURPOSE: To prospectively compare the sensitivity and specificity of ultrasonography (US) with those of contrast material-enhanced US in the depiction of solid organ injuries in children with blunt abdominal trauma, with contrast-enhanced computed tomography (CT) as the reference standard.
MATERIALS AND METHODS: The study protocol was approved by the ethics board, and written informed consent was obtained from parents. US, contrast-enhanced US, and contrast-enhanced CT were performed in 27 consecutive children (19 boys, eight girls; mean age, 8.9 years +/- 2.8 [standard deviation]) with blunt abdominal trauma to determine if solid abdominal organ injuries were present. Sensitivity, specificity, agreement, accuracy, number of lesions correctly identified, and positive and negative predictive values were determined for US and contrast-enhanced US, as compared with contrast-enhanced CT.
RESULTS: In 15 patients, contrast-enhanced CT findings were negative. Contrast-enhanced CT depicted 14 solid organ injuries in 12 patients. Lesions were in the spleen (n = 7), liver (n = 4), right kidney (n = 1), right adrenal gland (n = 1), and pancreas (n = 1). Contrast-enhanced US depicted 13 of the 14 lesions in 12 patients with positive contrast-enhanced CT findings and no lesions in the patients with negative contrast-enhanced CT findings. Unenhanced US depicted free fluid in two of 15 patients with negative contrast-enhanced CT findings and free fluid, parenchymal lesions, or both in eight of 12 patients with positive contrast-enhanced CT findings. Overall, the diagnostic performance of contrast-enhanced US was better than that of US, as sensitivity, specificity, and positive and negative predictive values were 92.2%, 100%, 100%, and 93.8%, respectively.
CONCLUSION: Contrast-enhanced US was almost as accurate as contrast-enhanced CT in depicting solid organ injuries in children. (c) RSNA, 2008.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18195385     DOI: 10.1148/radiol.2463070652

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  34 in total

1.  Contrast-enhanced ultrasound: The evolving applications.

Authors:  Hui-Xiong Xu
Journal:  World J Radiol       Date:  2009-12-31

Review 2.  Safety of contrast-enhanced ultrasound in children for non-cardiac applications: a review by the Society for Pediatric Radiology (SPR) and the International Contrast Ultrasound Society (ICUS).

Authors:  Kassa Darge; Frederica Papadopoulou; Aikaterini Ntoulia; Dorothy I Bulas; Brian D Coley; Lynn A Fordham; Harriet J Paltiel; Beth McCarville; Frank M Volberg; David O Cosgrove; Barry B Goldberg; Stephanie R Wilson; Steven B Feinstein
Journal:  Pediatr Radiol       Date:  2013-07-11

Review 3.  Contrast-enhanced ultrasound (CEUS) in pediatric blunt abdominal trauma.

Authors:  Margherita Trinci; Claudia Lucia Piccolo; Riccardo Ferrari; Michele Galluzzo; Stefania Ianniello; Vittorio Miele
Journal:  J Ultrasound       Date:  2018-12-08

Review 4.  Contrast-enhanced ultrasound of blunt abdominal trauma in children.

Authors:  Harriet J Paltiel; Richard A Barth; Costanza Bruno; Aaron E Chen; Annamaria Deganello; Zoltan Harkanyi; M Katherine Henry; Damjana Ključevšek; Susan J Back
Journal:  Pediatr Radiol       Date:  2021-05-12

5.  Role of contrast enhanced ultrasound in acute scrotal diseases.

Authors:  Massimo Valentino; Michele Bertolotto; Lorenzo Derchi; Alessandro Bertaccini; Pietro Pavlica; Giuseppe Martorana; Libero Barozzi
Journal:  Eur Radiol       Date:  2011-06-02       Impact factor: 5.315

Review 6.  Paediatric gastrointestinal and hepatobiliary radiology: why do we need subspecialists, and what is new?

Authors:  Tom A Watson; Joy Barber; Helen Woodley
Journal:  Pediatr Radiol       Date:  2021-03-20

7.  Contrast-enhanced US evaluation in patients with blunt abdominal trauma().

Authors:  M Valentino; C De Luca; S Sartoni Galloni; M Branchini; C Modolon; P Pavlica; L Barozzi
Journal:  J Ultrasound       Date:  2010-07-08

8.  Accuracy of contrast-enhanced ultrasound (CEUS) in the identification and characterization of traumatic solid organ lesions in children: a retrospective comparison with baseline US and CE-MDCT.

Authors:  Guendalina Menichini; Barbara Sessa; Margherita Trinci; Michele Galluzzo; Vittorio Miele
Journal:  Radiol Med       Date:  2015-03-31       Impact factor: 3.469

9.  Contrast-enhanced ultrasonography in blunt abdominal trauma: considerations after 5 years of experience.

Authors:  M Valentino; L Ansaloni; F Catena; P Pavlica; A D Pinna; L Barozzi
Journal:  Radiol Med       Date:  2009-09-22       Impact factor: 3.469

10.  Comparison between MRI and CEUS in the follow-up of patients with blunt abdominal trauma managed conservatively.

Authors:  Vittorio Miele; Claudia Lucia Piccolo; Barbara Sessa; Margherita Trinci; Michele Galluzzo
Journal:  Radiol Med       Date:  2015-08-08       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.