Literature DB >> 18195248

Diagnostic quality of multiplanar reformations obtained with a newly developed cone beam device for maxillofacial imaging.

R A Mischkowski1, P Scherer, L Ritter, J Neugebauer, E Keeve, J E Zöller.   

Abstract

OBJECTIVES: To compare the diagnostic quality of multiplanar reformations generated by a newly developed cone beam device with the diagnostic quality of multiplanar reformations obtained using a state of the art multidetector row CT scanner.
METHODS: Digital volume tomograms (DVTs) were obtained with the prototype of GALILEOS (Sirona Dental Systems Inc., Bensheim, Germany), a newly developed compact-sized cone beam machine with a scan volume of 15 x 15 x 15 cm. CT scans were performed for comparison with two 16-detector row CT scanners. The study included 30 image pairs obtained from the same patients. The multiplanar reformations in axial, coronal and sagittal planes were subjectively assessed by 3 observers using a 1(excellent)-5(poor) scale on 35 weighted criteria including findings detection, image quality and visualization of several anatomical structures.
RESULTS: There was no statistically significant difference between DVT and CT in cumulative values expressing the diagnostic quality of the reformations (P = 0.071). The interobserver agreement was better with CT than with DVT. Findings detection and the visualization of the majority of anatomical structures within the mandibulomaxillary area were ranked at the same level for DVT as with CT.
CONCLUSIONS: The diagnostic quality of multiplanar reformations can be considered the same in both devices. Although sharpness, noise level and contrast resolution do not reach the level of CT, DVT images proved statistically not inferior for the detection of lesions which may be adequately depicted by both imaging modes.

Entities:  

Mesh:

Year:  2008        PMID: 18195248     DOI: 10.1259/dmfr/25381129

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  9 in total

1.  A suggested technique for the application of the cone beam computed tomography periapical index.

Authors:  S Esposito; M Cardaropoli; E Cotti
Journal:  Dentomaxillofac Radiol       Date:  2011-12       Impact factor: 2.419

2.  Accuracy assessment of the axial images obtained from cone beam computed tomography.

Authors:  Francine Kühl Panzarella; J L C Junqueira; L B Oliveira; N S de Araújo; C Costa
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

3.  Metal and motion artifacts by cone beam computed tomography (CBCT) in dental and maxillofacial study.

Authors:  Cosimo Nardi; Claudia Borri; Francesco Regini; Linda Calistri; Alessandro Castellani; Chiara Lorini; Stefano Colagrande
Journal:  Radiol Med       Date:  2015-01-30       Impact factor: 3.469

4.  The nasal septum deviation index (NSDI) based on CBCT data.

Authors:  Marina Codari; Matteo Zago; Giulia A Guidugli; Valentina Pucciarelli; Gianluca M Tartaglia; Francesco Ottaviani; Stefano Righini; Chiarella Sforza
Journal:  Dentomaxillofac Radiol       Date:  2015-12-21       Impact factor: 2.419

5.  Anatomical variation of mandibular canal simulating a recurrence of odontogenic tumor.

Authors:  Douglas Magno Guimarães; Flávia Sirotheau Correa Pontes; Diogo Dos Santos Da Mata Rezende; Helder Antonio Rebelo Pontes
Journal:  Ann Maxillofac Surg       Date:  2014-01

6.  Prevalence of Soft Tissue Calcifications in CBCT Images of Mandibular Region.

Authors:  Leila Khojastepour; Abdolaziz Haghnegahdar; Hamed Sayar
Journal:  J Dent (Shiraz)       Date:  2017-06

7.  Influence of tooth position within the field of view on the intensity of cone-beam computed tomographic imaging artifacts when assessing teeth restored with various intracanal materials.

Authors:  Martina Gerlane de Oliveira Pinto; Saulo Leonardo Sousa Melo; Yuri Wanderley Cavalcanti; Elisa Diniz de Lima; Patrícia Meira Bento; Daniela Pita de Melo
Journal:  Imaging Sci Dent       Date:  2020-06-18

8.  Agreement between cone-beam computed tomography and functional endoscopic sinus surgery for detection of pathologies and anatomical variations of the paranasal sinuses in chronic rhinosinusitis patients: A prospective study.

Authors:  Nafiseh Nikkerdar; Nastaran Eivazi; Mohana Lotfi; Amin Golshah
Journal:  Imaging Sci Dent       Date:  2020-12-15

9.  Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects.

Authors:  Roghieh Bardal; Hassan Jahanihashemi; Maryam Mostafavi; Esmaeil Kalhor; Maryam Tofangchiha; Mahdieh Dehghani
Journal:  J Dent (Tehran)       Date:  2015-11
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.