Literature DB >> 18194389

Performance evaluation of the new fully automated human immunodeficiency virus antigen-antibody combination assay designed for blood screening.

Eva Sickinger1, Gesa Jonas, Alex W Yem, Andreas Goller, Myriam Stieler, Catherine Brennan, Michael Hausmann, Gerald Schochetman, Sushil G Devare, Jeffery C Hunt, Hans-Peter Kapprell, Jane D Bryant.   

Abstract

BACKGROUND: Before the introduction of human immunodeficiency virus (HIV) combination assays, serologic diagnosis of HIV infection was performed with assays that detected either antibodies or p24 antigen. Owing to the capability to detect the early appearance of p24 antigen, combination assays that are designed for simultaneous detection of antibodies and antigen can significantly reduce the diagnostic window. STUDY DESIGN AND METHODS: Specificity and sensitivity of a commercially available HIV antigen-antibody combination assay (Abbott PRISM; assay is not licensed by the FDA for use in the United States) were evaluated in a multicenter study by testing volunteer blood donors, hospitalized patients, seroconversion panels, and p24 antigen and HIV antibody subtype panels. Performance data were compared to a commercially available HIV combination assay and the PRISM HIV O Plus assay.
RESULTS: Apparent specificity of 99.95 percent was observed in the donor population for the PRISM HIV antigen-antibody combination assay, and better seroconversion sensitivity was demonstrated compared with another combination assay and the PRISM HIV O Plus assay. Analytical HIV antigen detection sensitivity averaged 33 pg per mL on the Agence Française de Sécurité Sanitaire des Produits de Santé (AFSSAPS) panel. Furthermore, comparable antigen sensitivity was demonstrated for 32 HIV-1 group M subtype and group O panels. The PRISM HIV combination assay detected all HIV-1 group M and O and HIV-2 antibody-positive specimens evaluated.
CONCLUSIONS: The PRISM HIV antigen-antibody combination assay demonstrated a significant reduction of the window period for diagnosis of HIV infection. The assay demonstrated enhanced specificity and sensitivity along with broad subtype detection. The assay performance represents the "state-of-the art" technology for serologic blood screening of HIV infection.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18194389     DOI: 10.1111/j.1537-2995.2007.01583.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  8 in total

1.  A conceptual model of interventions to increase diagnosis of acute HIV infection and reduce forward transmission.

Authors:  Andrew E Petroll; Steven D Pinkerton
Journal:  AIDS Behav       Date:  2011-11

2.  Challenges for rapid molecular HIV diagnostics.

Authors:  Marco L Schito; M Patricia D'Souza; S Michele Owen; Michael P Busch
Journal:  J Infect Dis       Date:  2010-04-15       Impact factor: 5.226

Review 3.  Should we treat acute HIV infection?

Authors:  Meagan O'Brien; Martin Markowitz
Journal:  Curr HIV/AIDS Rep       Date:  2012-06       Impact factor: 5.071

4.  Performance of parallel screening of Brazilian blood donors with two human immunodeficiency virus immunoassays: implications for sequential immunoassay testing algorithms in other countries.

Authors:  Ester C Sabino; Nanci A Salles; Cesar de Almeida-Neto; Angela M Barreto; Fernando Basques; Emanuelle A Barros; Alfredo Mendrone; Michael P Busch
Journal:  Transfusion       Date:  2011-01       Impact factor: 3.157

Review 5.  Acute HIV-1 Infection.

Authors:  Myron S Cohen; George M Shaw; Andrew J McMichael; Barton F Haynes
Journal:  N Engl J Med       Date:  2011-05-19       Impact factor: 91.245

6.  Performance evaluation of a new fourth-generation HIV combination antigen-antibody assay.

Authors:  A Mühlbacher; H Schennach; J van Helden; T Hebell; G Pantaleo; P Bürgisser; C Cellerai; P Permpikul; M I Rodriguez; A Eiras; F Alborino; P Cunningham; M Axelsson; S Andersson; O Wetlitzky; C Kaiser; P Möller; G de Sousa
Journal:  Med Microbiol Immunol       Date:  2012-06-17       Impact factor: 3.402

7.  Seroprevalence of human immunodeficiency virus in north Indian blood donors using third and fourth generation Enzyme linked immunosorbent assay.

Authors:  Sheetal Malhotra; Neelam Marwaha; Karan Saluja
Journal:  Asian J Transfus Sci       Date:  2013-07

Review 8.  Primary HIV Infection: Clinical Presentation, Testing, and Treatment.

Authors:  Aurélia Henn; Clara Flateau; Sébastien Gallien
Journal:  Curr Infect Dis Rep       Date:  2017-09-07       Impact factor: 3.663

  8 in total