Literature DB >> 18191032

Force differentiation in recognition of cross-reactive antigens by magnetic beads.

Tamara Y Morozova1, Victor N Morozov.   

Abstract

Functionalized magnetic beads have been suggested recently as active labels for extremely rapid and highly sensitive immunoassay. Here we addressed the problem of specificity and cross-reactivity in such detection, which (unlike conventional immunoassay methods) cannot rely on a difference in the equilibrium binding constants to distinguish between closely related antigens. Microarrays containing spots of nine albumins from sera of different mammals (human, bovine, sheep, goat, pig, dog, rabbit, rat, and mouse) were tested for their interaction with magnetic beads functionalized with monoclonal antibodies against bovine or human serum albumin. It was demonstrated that the magnetic beads bound only those albumin spots to which antibody was reactive or cross-reactive in enzyme-linked immunosorbent assay (ELISA). The effect of cross-reactivity in the assay with magnetic beads detection could be decreased substantially by placing the array into a flow cell and subjecting the tethered beads to increasing shear flow, which removed beads first from the weakest cross-reactive antigens and then from more strong ones. Partial blocking of the antibody molecules on the bead surface was shown to reduce critical shear stress necessary to remove beads from the specific antigens, indicating that multiple antigen-antibody bonds held the beads on the array surface.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18191032     DOI: 10.1016/j.ab.2007.12.007

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  3 in total

1.  Optimization of antibody-conjugated magnetic nanoparticles for target preconcentration and immunoassays.

Authors:  Joshua E Smith; Kim E Sapsford; Weihong Tan; Frances S Ligler
Journal:  Anal Biochem       Date:  2010-11-13       Impact factor: 3.365

2.  ELIME (enzyme linked immuno magnetic electrochemical) method for mycotoxin detection.

Authors:  Daniela Romanazzo; Francesco Ricci; Silvia Vesco; Silvia Piermarini; Giulia Volpe; Danila Moscone; Giuseppe Palleschi
Journal:  J Vis Exp       Date:  2009-10-23       Impact factor: 1.355

3.  High performance wash-free magnetic bioassays through microfluidically enhanced particle specificity.

Authors:  Daniel J B Bechstein; Jung-Rok Lee; Chin Chun Ooi; Adi W Gani; Kyunglok Kim; Robert J Wilson; Shan X Wang
Journal:  Sci Rep       Date:  2015-06-30       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.