Immunosensor for the determination of Staphylococcus aureus using a tyrosinase-mercaptopropionic acid modified electrode as an amperometric transducer.

Vanessa Escamilla-Gómez1, Susana Campuzano, María Pedrero, José M Pingarrón.   

Abstract

An amperometric immunosensor for the quantification of Staphylococcus aureus based on the coimmobilization of rabbit immunoglobulin G (RbIgG) and tyrosinase on a mercaptopropionic acid self-assembled monolayer modified gold electrode is reported. A competitive mode in which protein-A-bearing S. aureus cells and antiRbIgG labeled with alkaline phosphatase (AP) compete for the binding sites of immobilized RbIgG was used. Monitoring of the affinity reaction was carried out by the amperometric detection at -0.15 V of phenol generated in the enzyme reaction with AP, at the tyrosinase-modified electrode through the electrochemical reduction of the o-quinone formed. Optimization of the working variables, such as the immunosensor composition and incubation times, the applied potential, the working pH and the concentration of phenyl phosphate used as the AP substrate, was carried out. Under the optimized conditions, both the repeatability of the measurements and the reproducibility of the responses obtained with different immunosensors yielded relative standard deviation values for the steady-state current lower than 10%. The immunosensor showed a dynamic range from 4.4x10(5) to 1.8x10(7) S. aureus cells mL(-1), with a detection limit of 1.7x10(5) cells mL(-1). The limit of detection was remarkably improved by subjecting S. aureus cells to wall lysis by heat treatment. The value obtained was 2.3x10(3) cells mL(-1), which is adequate for the monitoring of S. aureus contamination levels in some foodstuffs. As an application, milk samples spiked with bacteria at the 4.8x10(3) cells mL(-1) level were analyzed.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18189127     DOI: 10.1007/s00216-007-1810-1

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

Review 1.  Moving towards the immunodiagnosis of staphylococcal intramammary infections.

Authors:  M H Fabres-Klein; A P Aguilar; M P Silva; D M Silva; A O B Ribon
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2014-06-20       Impact factor: 3.267

Review 2.  State-of-the-art of (bio)chemical sensor developments in analytical Spanish groups.

Authors:  María Reyes Plata; Ana María Contento; Angel Ríos
Journal:  Sensors (Basel)       Date:  2010-03-24       Impact factor: 3.576

3.  Potentiometric Aptasensing of Vibrio alginolyticus Based on DNA Nanostructure-Modified Magnetic Beads.

Authors:  Guangtao Zhao; Jiawang Ding; Han Yu; Tanji Yin; Wei Qin
Journal:  Sensors (Basel)       Date:  2016-12-02       Impact factor: 3.576

4.  Electrochemical immunosensor based on an antibody-hierarchical mesoporous SiO2 for the detection of Staphylococcus aureus.

Authors:  Hongsu Wang; Yi Xiu; Yan Chen; Liping Sun; Libin Yang; Honghao Chen; Xiaodi Niu
Journal:  RSC Adv       Date:  2019-05-24       Impact factor: 4.036

5.  Integrated Experimental and Theoretical Studies on an Electrochemical Immunosensor.

Authors:  Neda Rafat; Paul Satoh; Scott Calabrese Barton; Robert Mark Worden
Journal:  Biosensors (Basel)       Date:  2020-10-17