Literature DB >> 18187344

Integrated SENSE DTI with correction of susceptibility- and eddy current-induced geometric distortions.

Trong-Kha Truong1, Bin Chen, Allen W Song.   

Abstract

Diffusion tensor imaging (DTI) is vulnerable to geometric distortions caused by subject-dependent susceptibility effects and diffusion-weighting direction-dependent eddy currents. Although the introduction of sensitivity encoding (SENSE) has reduced the overall distortions for the same imaging matrix size, this benefit is offset by the increasing demand for higher spatial resolution. Thus, significant distortions remain or are exacerbated in high-resolution SENSE DTI acquisitions. While the susceptibility-induced distortions cause global spatial misregistration, the direction-dependent eddy current-induced distortions cause misregistration among different diffusion-weighted images, leading to errors in the derivation of the diffusion tensor in virtually all voxels, and consequently in resulting diffusion parameters as well as in fiber tracking. Here, we apply a comprehensive approach that corrects for both susceptibility- and eddy current-induced distortions to high-resolution SENSE DTI acquisitions, and demonstrate its effectiveness, efficiency, and reliability in vivo as well as its advantages over a twice-refocused spin-echo sequence. This method should find increased use in modern DTI experiments where SENSE acquisitions are commonly used.

Mesh:

Year:  2007        PMID: 18187344      PMCID: PMC2859889          DOI: 10.1016/j.neuroimage.2007.12.001

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  19 in total

1.  Mapping eddy current induced fields for the correction of diffusion-weighted echo planar images.

Authors:  M A Horsfield
Journal:  Magn Reson Imaging       Date:  1999-11       Impact factor: 2.546

Review 2.  Diffusion tensor imaging: concepts and applications.

Authors:  D Le Bihan; J F Mangin; C Poupon; C A Clark; S Pappata; N Molko; H Chabriat
Journal:  J Magn Reson Imaging       Date:  2001-04       Impact factor: 4.813

3.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

4.  How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging.

Authors:  Jesper L R Andersson; Stefan Skare; John Ashburner
Journal:  Neuroimage       Date:  2003-10       Impact factor: 6.556

5.  Diffusion tensor imaging using single-shot SENSE-EPI.

Authors:  Roland Bammer; Martin Auer; Stephen L Keeling; Michael Augustin; Lara A Stables; Rupert W Prokesch; Rudolf Stollberger; Michael E Moseley; Franz Fazekas
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

6.  SENSE-DTI at 3 T.

Authors:  T Jaermann; G Crelier; K P Pruessmann; X Golay; T Netsch; A M C van Muiswinkel; S Mori; P C M van Zijl; A Valavanis; S Kollias; P Boesiger
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

7.  Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity.

Authors:  Nils Bodammer; Jörn Kaufmann; Martin Kanowski; Claus Tempelmann
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

8.  Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo.

Authors:  T G Reese; O Heid; R M Weisskoff; V J Wedeen
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

9.  Correction for distortion of echo-planar images used to calculate the apparent diffusion coefficient.

Authors:  J C Haselgrove; J R Moore
Journal:  Magn Reson Med       Date:  1996-12       Impact factor: 4.668

10.  Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI.

Authors:  G K Rohde; A S Barnett; P J Basser; S Marenco; C Pierpaoli
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

View more
  10 in total

1.  Temporal lobe white matter asymmetry and language laterality in epilepsy patients.

Authors:  Timothy M Ellmore; Michael S Beauchamp; Joshua I Breier; Jeremy D Slater; Giridhar P Kalamangalam; Thomas J O'Neill; Michael A Disano; Nitin Tandon
Journal:  Neuroimage       Date:  2009-10-27       Impact factor: 6.556

2.  Dynamic correction of artifacts due to susceptibility effects and time-varying eddy currents in diffusion tensor imaging.

Authors:  Trong-Kha Truong; Nan-kuei Chen; Allen W Song
Journal:  Neuroimage       Date:  2011-06-14       Impact factor: 6.556

3.  Localized high-resolution DTI of the human midbrain using single-shot EPI, parallel imaging, and outer-volume suppression at 7T.

Authors:  Christopher J Wargo; John C Gore
Journal:  Magn Reson Imaging       Date:  2013-03-29       Impact factor: 2.546

4.  Application of k-space energy spectrum analysis for inherent and dynamic B0 mapping and deblurring in spiral imaging.

Authors:  Trong-Kha Truong; Nan-Kuei Chen; Allen W Song
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

Review 5.  Diffusion tensor imaging of cerebral white matter integrity in cognitive aging.

Authors:  David J Madden; Ilana J Bennett; Agnieszka Burzynska; Guy G Potter; Nan-Kuei Chen; Allen W Song
Journal:  Biochim Biophys Acta       Date:  2011-08-16

6.  Anomalous diffusion measured by a twice-refocused spin echo pulse sequence: analysis using fractional order calculus.

Authors:  Qing Gao; Girish Srinivasan; Richard L Magin; Xiaohong Joe Zhou
Journal:  J Magn Reson Imaging       Date:  2011-05       Impact factor: 4.813

Review 7.  Cerebral white matter integrity and cognitive aging: contributions from diffusion tensor imaging.

Authors:  David J Madden; Ilana J Bennett; Allen W Song
Journal:  Neuropsychol Rev       Date:  2009-08-25       Impact factor: 7.444

8.  Dynamic and inherent B0 correction for DTI using stimulated echo spiral imaging.

Authors:  Alexandru V Avram; Arnaud Guidon; Trong-Kha Truong; Chunlei Liu; Allen W Song
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

9.  Repeatability and reproducibility of prospective motion- and shim corrected 2D glycoCEST MRI.

Authors:  Gizeaddis Lamesgin Simegn; Ali Alhamud; Andre J W van der Kouwe; Ernesta Meintjes; Frances Robertson
Journal:  Quant Imaging Med Surg       Date:  2019-10

10.  A hitchhiker's guide to diffusion tensor imaging.

Authors:  José M Soares; Paulo Marques; Victor Alves; Nuno Sousa
Journal:  Front Neurosci       Date:  2013-03-12       Impact factor: 4.677

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.