Literature DB >> 18185931

Total knee arthroplasty using cementless keels and cemented tibial trays: 10-year results.

Frank R Kolisek1, Michael A Mont, Thorsten M Seyler, David R Marker, Nenette M Jessup, Junaed A Siddiqui, Eric Monesmith, Slif D Ulrich.   

Abstract

The problem of early mechanical stability of cemented and cementless keels of the tibial component in total knee arthroplasty (TKA) is controversial. The purpose of this study was to assess clinical and radiographic outcomes of a cohort of 51 TKAs using a cemented platform with cementless keel fixation. At a mean follow-up of 10.4 years (range, 7 to 14 years), the mean Knee Society Score (KSS) was 93 points (range, 59 to 100 points), and the mean functional score was 73 points (range, 0 to 100 points). Only one patient demonstrated progressive tibial radiolucencies at 13.1 years follow-up, which resolved with a revision with an exchange of components. The results of this study suggest that a proximally cemented tibial tray with a press-fit keel TKA provides excellent mean 10-year outcomes.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18185931      PMCID: PMC2899213          DOI: 10.1007/s00264-007-0502-y

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  22 in total

1.  Problems with cementless total knee arthroplasty at 11 years followup.

Authors:  R A Berger; J H Lyon; J J Jacobs; R M Barden; E M Berkson; M B Sheinkop; A G Rosenberg; J O Galante
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

2.  Early failures in total knee arthroplasty.

Authors:  T K Fehring; S Odum; W L Griffin; J B Mason; M Nadaud
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

3.  Tibial component fixation with cement: full- versus surface-cementation techniques.

Authors:  Christopher L Peters; Marcis A Craig; R Alexander Mohr; Kent N Bachus
Journal:  Clin Orthop Relat Res       Date:  2003-04       Impact factor: 4.176

4.  Cementless total knee arthroplasty with Profix: a 8- to 10-year follow-up study.

Authors:  François Hardeman; Hilde Vandenneucker; Johan Van Lauwe; Johan Bellemans
Journal:  Knee       Date:  2006-10-24       Impact factor: 2.199

5.  An analysis of tibial component design in total knee arthroplasty.

Authors:  K Murase; R D Crowninshield; D R Pedersen; T S Chang
Journal:  J Biomech       Date:  1983       Impact factor: 2.712

6.  Cementless total knee arthroplasty in patients 50 years or younger.

Authors:  Aaron A Hofmann; Scott M Heithoff; Marcelo Camargo
Journal:  Clin Orthop Relat Res       Date:  2002-11       Impact factor: 4.176

7.  Loosening and osteolysis with the press-fit condylar posterior-cruciate-substituting total knee replacement.

Authors:  S A Mikulak; O M Mahoney; M A dela Rosa; T P Schmalzried
Journal:  J Bone Joint Surg Am       Date:  2001-03       Impact factor: 5.284

8.  Uncemented rotating-platform total knee replacement: a five to twelve-year follow-up study.

Authors:  R Barry Sorrells; Paul E Voorhorst; Jeffrey A Murphy; Maryrose P Bauschka; A Seth Greenwald
Journal:  J Bone Joint Surg Am       Date:  2004-10       Impact factor: 5.284

9.  Effects of tibial components on load transfer in the upper tibia.

Authors:  D Reilly; P S Walker; M Ben-Dov; F C Ewald
Journal:  Clin Orthop Relat Res       Date:  1982-05       Impact factor: 4.176

10.  A randomised, controlled trial of cemented versus cementless press-fit condylar total knee replacement. Ten-year survival analysis.

Authors:  F M Khaw; L M G Kirk; R W Morris; P J Gregg
Journal:  J Bone Joint Surg Br       Date:  2002-07
View more
  8 in total

1.  Comparison of cementing techniques of the tibial component in total knee replacement.

Authors:  Tuuli Saari; Ming Guo Li; David Wood; Bo Nivbrant
Journal:  Int Orthop       Date:  2008-08-15       Impact factor: 3.075

2.  CORR Insights ®: Loss of cement-bone interlock in retrieved tibial components from total knee arthroplasties.

Authors:  Ross Crawford
Journal:  Clin Orthop Relat Res       Date:  2013-09-26       Impact factor: 4.176

3.  Scorpio single radius total knee arthroplasty. A minimal five-year follow-up multicentric study.

Authors:  Frédéric Borrione; Paul Bonnevialle; Christian Mabit; Olivier Guingand; Denis Bertin; François Bonnomet; Christophe Denis; Gilles Gagna
Journal:  Int Orthop       Date:  2011-03-02       Impact factor: 3.075

4.  Comparison between uncemented and cemented fixation for the tibial component in distal femoral replacement: a clinical and radiological study.

Authors:  Haijie Liang; Wei Guo; Rongli Yang; Xiaodong Tang; Taiqiang Yan
Journal:  Int Orthop       Date:  2018-02-24       Impact factor: 3.075

5.  The effect of multiple drilling on a sclerotic proximal tibia during total knee arthroplasty.

Authors:  Ji Hyun Ahn; Seung Hyo Jeong; Sung Hyun Lee
Journal:  Int Orthop       Date:  2014-10-11       Impact factor: 3.075

6.  The use of a modular titanium baseplate with a press-fit keel implanted with a surface cementing technique for primary total knee arthroplasty.

Authors:  Christopher E Pelt; Jill Erickson; Bryt A Christensen; Benjamin Widmer; Erik P Severson; David Evans; Christopher L Peters
Journal:  Biomed Res Int       Date:  2014-05-14       Impact factor: 3.411

7.  Reduced tibial strain-shielding with extraosseous total knee arthroplasty revision system.

Authors:  Tomas A Correa; Bidyut Pal; Richard J van Arkel; Felice Vanacore; Andrew A Amis
Journal:  Med Eng Phys       Date:  2018-10-10       Impact factor: 2.242

8.  Tibial cleaning method for cemented total knee arthroplasty: An experimental study.

Authors:  Peter Helwig; Lukas Konstantinidis; Anja Hirschmüller; Verena Miltenberger; Kerstin Kuminack; Norbert P Südkamp; Oliver Hauschild
Journal:  Indian J Orthop       Date:  2013-01       Impact factor: 1.251

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.