Literature DB >> 18183963

Unexpected analyte oxidation during desorption electrospray ionization-mass spectrometry.

Sofie P Pasilis1, Vilmos Kertesz, Gary J Van Berkel.   

Abstract

During the analysis of surface-spotted analytes using desorption electrospray ionization-mass spectrometry (DESI-MS), abundant ions are sometimes observed that appear to be the result of oxygen addition reactions. In this investigation, the effect of sample aging, the ambient lab environment, spray voltage, analyte surface concentration, and surface type on this oxidative modification of spotted analytes, exemplified by tamoxifen and reserpine, during analysis by DESI-MS was studied. Simple exposure of the samples to air and to ambient lighting increased the extent of oxidation. Increased spray voltage also led to increased analyte oxidation, possibly as a result of oxidative species formed electrochemically at the emitter electrode or in the gas phase by discharge processes. These oxidative species are carried by the spray and impinge on and react with the sampled analyte during desorption/ionization. The relative abundance of oxidized species was more significant for the analysis of deposited analyte having a relatively low surface concentration. Increasing the spray solvent flow rate and the addition of hydroquinone as a redox buffer to the spray solvent were found to decrease, but not entirely eliminate, analyte oxidation during analysis. The major parameters that both minimize and maximize analyte oxidation were identified, and DESI-MS operational recommendations to avoid these unwanted reactions are suggested.

Entities:  

Year:  2008        PMID: 18183963     DOI: 10.1021/ac701791w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  12 in total

1.  Deconstructing desorption electrospray ionization: independent optimization of desorption and ionization by spray desorption collection.

Authors:  Kevin A Douglass; Shashank Jain; William R Brandt; Andre R Venter
Journal:  J Am Soc Mass Spectrom       Date:  2012-08-21       Impact factor: 3.109

2.  Oxidative Ionization Under Certain Negative-Ion Mass Spectrometric Conditions.

Authors:  Isra Hassan; Julius Pavlov; Ramu Errabelli; Athula B Attygalle
Journal:  J Am Soc Mass Spectrom       Date:  2016-11-07       Impact factor: 3.109

3.  Manganese oxide nanoparticle-assisted laser desorption/ionization mass spectrometry for medical applications.

Authors:  Shu Taira; Kenji Kitajima; Hikaru Katayanagi; Eiichiro Ichiishi; Yuko Ichiyanagi
Journal:  Sci Technol Adv Mater       Date:  2009-07-14       Impact factor: 8.090

Review 4.  Mass spectrometry imaging under ambient conditions.

Authors:  Chunping Wu; Allison L Dill; Livia S Eberlin; R Graham Cooks; Demian R Ifa
Journal:  Mass Spectrom Rev       Date:  2012-09-20       Impact factor: 10.946

5.  Investigation and Applications of In-Source Oxidation in Liquid Sampling-Atmospheric Pressure Afterglow Microplasma Ionization (LS-APAG) Source.

Authors:  Xiaobo Xie; Zhenpeng Wang; Yafeng Li; Lingpeng Zhan; Zongxiu Nie
Journal:  J Am Soc Mass Spectrom       Date:  2016-12-19       Impact factor: 3.109

6.  Cardiolipins Are Biomarkers of Mitochondria-Rich Thyroid Oncocytic Tumors.

Authors:  Jialing Zhang; Wendong Yu; Seung Woo Ryu; John Lin; Gerardo Buentello; Robert Tibshirani; James Suliburk; Livia S Eberlin
Journal:  Cancer Res       Date:  2016-09-22       Impact factor: 12.701

7.  Desorption electrospray ionization mass spectrometry for monitoring the kinetics of Baeyer-Villiger solid-state organic reactions.

Authors:  Ying Xie; Li-Fang He; Shui-Chao Lin; Hai-Feng Su; Su-Yuan Xie; Rong-Bin Huang; Lan-Sun Zheng
Journal:  J Am Soc Mass Spectrom       Date:  2009-07-18       Impact factor: 3.109

8.  Ambient analysis of saturated hydrocarbons using discharge-induced oxidation in desorption electrospray ionization.

Authors:  Chunping Wu; Kuangnan Qian; Marcela Nefliu; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2009-11-13       Impact factor: 3.109

9.  Ascorbic acid for homogenous redox buffering in electrospray ionization-mass spectrometry.

Authors:  Sabine Plattner; Robert Erb; Jean-Pierre Chervet; Herbert Oberacher
Journal:  Anal Bioanal Chem       Date:  2012-07-08       Impact factor: 4.142

10.  Going beyond electrospray: mass spectrometric studies of chemical reactions in and on liquids.

Authors:  Andrew J Ingram; Cornelia L Boeser; Richard N Zare
Journal:  Chem Sci       Date:  2015-10-01       Impact factor: 9.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.