Literature DB >> 18182336

Novel sphene coatings on Ti-6Al-4V for orthopedic implants using sol-gel method.

Chengtie Wu1, Yogambha Ramaswamy, David Gale, Wenrong Yang, Keqin Xiao, Liangchi Zhang, Yongbai Yin, Hala Zreiqat.   

Abstract

Hydroxyapatite (HAp) is commonly used to coat titanium alloys (Ti-6Al-4V) for orthopedic implants. However, their poor adhesion strength and insufficient long-term stability limit their application. Novel sphene (CaTiSiO5) ceramics possess excellent chemical stability and cytocompatibility. The aim of this study is to use the novel sphene ceramics as coatings for Ti-6Al-4V. The sol-gel method was used to produce the coatings and the thermal properties, phase composition, microstructure, thickness, surface roughness and adhesion strength of sphene coatings were analyzed by differential thermal analysis-thermal gravity (DTA-TG), X-ray diffraction (XRD), scanning electron microscopy (SEM), atom force microscopy (AFM) and scratch test, respectively. DTA analysis confirmed that the temperature of the sphene phase formation is 875 degrees C and XRD analysis indicated pure sphene coatings were obtained. A uniform structure of the sphene coating was found across the Ti-6Al-4V surface, with a thickness and surface roughness of the coating of about 0.5-1 microm and 0.38 microm, respectively. Sphene-coated Ti-6Al-4V possessed a significantly improved adhesion strength compared to that for HAp coating and their chemical stability was evaluated by testing the profile element distribution and the dissolution kinetics of calcium (Ca) ions after soaking the sphene-coated Ti-6Al-4V in Tris-HCl solution. Sphene coatings had a significantly improved chemical stability compared to the HAp coatings. A layer of apatite formed on the sphene-coated Ti-6Al-4V after they were soaked in simulated body fluids (SBF). Our results indicate that sol-gel coating of novel sphene onto Ti-6Al-4V possessed improved adhesion strength and chemical stability, compared to HAp-coated Ti-6Al-4V prepared under the same conditions, suggesting their potential application as coatings for orthopedic implants.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18182336     DOI: 10.1016/j.actbio.2007.11.005

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  12 in total

1.  Electrophoretic deposition of porous CaO-MgO-SiO2 glass-ceramic coatings with B2O3 as additive on Ti-6Al-4V alloy.

Authors:  Wei Zhang; Xianchun Chen; Xiaoming Liao; Zhongbing Huang; Xiuli Dan; Guangfu Yin
Journal:  J Mater Sci Mater Med       Date:  2011-08-21       Impact factor: 3.896

2.  Nanostructured glass-ceramic coatings for orthopaedic applications.

Authors:  Guocheng Wang; Zufu Lu; Xuanyong Liu; Xiaming Zhou; Chuanxian Ding; Hala Zreiqat
Journal:  J R Soc Interface       Date:  2011-02-03       Impact factor: 4.118

3.  Plasma-sprayed CaTiSiO5 ceramic coating on Ti-6Al-4V with excellent bonding strength, stability and cellular bioactivity.

Authors:  Chengtie Wu; Yogambha Ramaswamy; Xuanyong Liu; Guocheng Wang; Hala Zreiqat
Journal:  J R Soc Interface       Date:  2009-02-06       Impact factor: 4.118

4.  An In Vivo Study in Rat Femurs of Bioactive Silicate Coatings on Titanium Dental Implants.

Authors:  Giulia Brunello; Lisa Biasetto; Hamada Elsayed; Elia Sbettega; Chiara Gardin; Anna Scanu; Simone Carmignato; Barbara Zavan; Stefano Sivolella
Journal:  J Clin Med       Date:  2020-04-29       Impact factor: 4.241

5.  Enhanced Tribological and Bacterial Resistance of Carbon Nanotube with Ceria- and Silver-Incorporated Hydroxyapatite Biocoating.

Authors:  Aditi Pandey; Anup Kumar Patel; Ariharan S; Vikram Kumar; Rajeev Kumar Sharma; Satish Kanhed; Vinod Kumar Nigam; Anup Keshri; Arvind Agarwal; Kantesh Balani
Journal:  Nanomaterials (Basel)       Date:  2018-05-24       Impact factor: 5.076

Review 6.  Bioactive Glass and Silicate-Based Ceramic Coatings on Metallic Implants: Open Challenge or Outdated Topic?

Authors:  Giulia Brunello; Hamada Elsayed; Lisa Biasetto
Journal:  Materials (Basel)       Date:  2019-09-10       Impact factor: 3.623

7.  Novel chitosan/diclofenac coatings on medical grade stainless steel for hip replacement applications.

Authors:  Matjaž Finšgar; Amra Perva Uzunalić; Janja Stergar; Lidija Gradišnik; Uroš Maver
Journal:  Sci Rep       Date:  2016-05-24       Impact factor: 4.379

Review 8.  Fabrication, Properties and Applications of Dense Hydroxyapatite: A Review.

Authors:  Mythili Prakasam; Janis Locs; Kristine Salma-Ancane; Dagnija Loca; Alain Largeteau; Liga Berzina-Cimdina
Journal:  J Funct Biomater       Date:  2015-12-21

Review 9.  Ion-Doped Silicate Bioceramic Coating of Ti-Based Implant.

Authors:  Hossein Mohammadi; Mohammadmajid Sepantafar
Journal:  Iran Biomed J       Date:  2016-03-16

Review 10.  Analytical Techniques for the Characterization of Bioactive Coatings for Orthopaedic Implants.

Authors:  Katja Andrina Kravanja; Matjaž Finšgar
Journal:  Biomedicines       Date:  2021-12-17
View more