Literature DB >> 18182181

The effect of load cycling on metal ceramic screw-retained implant restorations with unrestored and restored screw access holes.

Matthias Karl1, Friedrich Graef, Manfred G Wichmann, Siegfried M Heckmann.   

Abstract

STATEMENT OF PROBLEM: It has been shown that under cyclic loading, more chipping fractures of the veneer ceramic occur on the occlusal surface of screw-retained implant-supported fixed partial dentures (FPDs) with unrestored screw access holes (SAHs) than in cemented restorations. This lack of stability may result in esthetic and functional problems.
PURPOSE: The purpose of this study was to investigate whether, under dynamic loading, fewer chipping fractures occur on the occlusal surface of screw-retained ceramic veneered implant FPDs with restored SAHs than in those with unrestored SAHs.
MATERIAL AND METHODS: Twenty screw-retained ceramic veneered 5-unit FPDs were manufactured for a 3-implant situation and divided into 2 groups of 10 unrestored and 10 SAHs restored with adhesive composite resin restorations (Tetric Evo Ceram). A masticatory simulator was used to load the FPDs occlusal to the implant positions for 20,000 cycles with a force of 100 N applied for 1 second, followed by 1 second of no loading. Three prosthodontists evaluated the FPDs using a light microscope and a dental probe. The number of chipping fractures found were analyzed using a generalized linear model with Poisson response and log link function (alpha =.05).
RESULTS: Investigators found significantly more chipping fractures in the group of screw-retained FPDs with unrestored SAHs. The rate ratio of unrestored versus restored prostheses was 3.29 (P=.006).
CONCLUSIONS: Adhesive composite resin restorations can significantly reduce the number of chipping fractures occurring around the SAHs of screw-retained implant-supported restorations.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18182181     DOI: 10.1016/S0022-3913(08)60004-9

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  1 in total

1.  Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system.

Authors:  Jae-Hong Lee; Jong-Bin Lee; Man-Yong Kim; Joon-Ho Yoon; Seong-Ho Choi; Young-Taek Kim
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.