Literature DB >> 18181677

Influence of sampling time and ultrafiltration coefficient of the dialysis membrane on cardiac troponin I and T.

Giuseppe Lippi1, Nicola Tessitore, Martina Montagnana, Gian Luca Salvagno, Antonio Lupo, Gian Cesare Guidi.   

Abstract

CONTEXT: The measurement of cardiac troponin I (TnI) and T (TnT) is essential to diagnose, guide therapy, and predict outcomes of the acute coronary syndrome. Increased levels of troponins, especially TnT, are frequently observed in patients on chronic hemodialysis (HD), reflecting ongoing and subclinical myocardial damage.
OBJECTIVE: Because these markers are increasingly used for stratification of cardiac risk in these patients, their behavior during HD should be acknowledged to optimize their clinical usefulness.
DESIGN: TnI and TnT were measured in 34 patients pre-HD and post-HD by either high- or low-flux membranes. The post-HD concentrations were corrected for hemoconcentration.
RESULTS: Pre-HD levels above the 99th percentile reference limits of the general population of TnI (>0.06 ng/ mL) and TnT (>0.01 ng/mL) were observed in 9% (13% high-flux, 6% low-flux membranes) and 88% (94% high-flux; 83% low-flux membranes) of the patients, respectively. No significant difference was observed in mean pre-HD values between patients dialyzed by low- and high-flux membranes. The overall decrease post-HD of both troponins (-21% and -17% for TnI and TnT, respectively) only reached statistical significance in patients dialyzed by low-flux membranes (-27% and -37% for TnI and TnT, respectively). A significant correlation was observed between absolute variations of TnI and TnT pre-HD to post-HD.
CONCLUSIONS: Results of our investigation attest that high-flux membranes clear both troponins more efficiently from circulation than low-flux membranes. Therefore, sampling time and ultrafiltration coefficient of the HD membrane should be regarded as potential sources of variability in the clinical interpretation of troponin measurement in HD patients.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18181677     DOI: 10.5858/2008-132-72-IOSTAU

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  9 in total

1.  Determinants and prognostic significance of an intra-dialysis rise of cardiac troponin I measured by sensitive assay in hemodialysis patients.

Authors:  Solmaz Assa; Ron T Gansevoort; Ralf Westerhuis; Anneke C Muller Kobold; Adriaan A Voors; Paul E de Jong; Stephan J L Bakker; Casper F M Franssen
Journal:  Clin Res Cardiol       Date:  2013-02-09       Impact factor: 5.460

2.  Prognostic value of high-sensitive cardiac troponin I in asymptomatic chronic hemodialysis patients.

Authors:  Barbara Maresca; Andrea Manzione; Alessandra Moioli; Gerardo Salerno; Patrizia Cardelli; Giorgio Punzo; Simona Barberi; Paolo Menè
Journal:  J Nephrol       Date:  2019-04-24       Impact factor: 3.902

3.  Cardiac troponin I but not cardiac troponin T adheres to polysulfone dialyser membranes in an in vitro haemodialysis model: explanation for lower serum cTnI concentrations following dialysis.

Authors:  David C Gaze; Paul O Collinson
Journal:  Open Heart       Date:  2014-06-12

4.  Cardiac Troponin I: A Valuable Biomarker Indicating the Cardiac Involvement in Fabry Disease.

Authors:  Christian Tanislav; Dursun Guenduez; Christoph Liebetrau; Anne Kathrin Giese; Sabrina Eichler; Nicole Sieweke; Maria Speth; Timm Bauer; Christian Hamm; Arndt Rolfs
Journal:  PLoS One       Date:  2016-06-20       Impact factor: 3.240

Review 5.  Cardiac biomarkers in dialysis.

Authors:  Usman Mahmood; David W Johnson; Magid A Fahim
Journal:  AIMS Genet       Date:  2016-12-26

6.  Prognostic values of high sensitivity cardiac troponin T and I for long-term mortality in hemodialysis patients.

Authors:  Kajohnsak Noppakun; Kannika Ratnachina; Nichanan Osataphan; Arintaya Phrommintikul; Wanwarang Wongcharoen
Journal:  Sci Rep       Date:  2022-08-17       Impact factor: 4.996

7.  High-sensitivity troponins in dialysis patients: variation and prognostic value.

Authors:  Sunna Snaedal; Peter Bárány; Sigrún H Lund; Abdul R Qureshi; Olof Heimbürger; Peter Stenvinkel; Christian Löwbeer; Karolina Szummer
Journal:  Clin Kidney J       Date:  2020-12-12

8.  Variation in and prognostic importance of troponin T measured using a high-sensitivity assay in clinically stable haemodialysis patients.

Authors:  Martin Wolley; Ralph Stewart; Elizabeth Curry; James Davidson; Harvey White; Helen Pilmore
Journal:  Clin Kidney J       Date:  2012-11-07

9.  Serum cardiac troponin T and effective blood flow in stable extracorporeal dialysis patients.

Authors:  Alicja E Grzegorzewska; Krzysztof Cieszyński; Leszek Niepolski; Andrzej Kaczmarek; Anna Sowińska
Journal:  Int Urol Nephrol       Date:  2015-11-24       Impact factor: 2.370

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.