Literature DB >> 18176317

Following tracheal intubation, mucus flow is reversed in the semirecumbent position: possible role in the pathogenesis of ventilator-associated pneumonia.

Gianluigi Li Bassi1, Alberto Zanella, Massimo Cressoni, Mario Stylianou, Theodor Kolobow.   

Abstract

OBJECTIVES: Critically ill intubated patients are positioned in the semirecumbent position to prevent pneumonia. In tracheally intubated sheep, we investigated the effects of gravitational force on tracheal mucus transport and on bacterial colonization of the respiratory system.
DESIGN: Prospective randomized animal study.
SETTING: Animal research facility at the National Institutes of Health.
SUBJECTS: Sixteen healthy sheep.
INTERVENTIONS: Spontaneously breathing or mechanically ventilated sheep were randomized to be positioned with the orientation of the trachea above (40 degrees, trachea-up) or below (5 degrees, trachea-down) horizontal.
MEASUREMENTS AND MAIN RESULTS: Tracheal mucus velocity was measured through radiographic tracking of radiopaque tantalum disks, insufflated into the trachea. After 24 hrs, sheep were euthanized, and samples from the airways and lungs were taken for microbiological analysis. The proximal trachea was colonized in all sheep. In trachea-down sheep, all mucus moved toward the glottis at a mean velocity of 2.1 +/- 1.1 mm/min. When mucus reached the endotracheal tube, it either entered the endotracheal tube or was lodged at the inflated endotracheal tube cuff. In all trachea-up sheep, abnormal tracheal mucus clearance was found. Mucus, mostly on the nondependent part of the trachea, moved toward the glottis at an average velocity of 2.2 +/- 2.0 mm/min and constantly accumulated at the inflated endotracheal tube cuff. From the proximal trachea, mucus eventually moved toward the lungs on the dependent part of the trachea, leading to an "intratracheal route" of colonization of the lungs. Pneumonia was found in 6/8 of trachea-up sheep and the same microorganisms were isolated from the lungs and the proximal trachea. No pneumonia was found in trachea-down sheep (p = .007).
CONCLUSIONS: The study indicates that following tracheal intubation gravitational force influences tracheal mucus clearance. When the trachea is oriented above horizontal, a flow of mucus from the proximal trachea toward the lungs is highly associated with bacterial colonization of the airways and pneumonia.

Entities:  

Mesh:

Year:  2008        PMID: 18176317     DOI: 10.1097/01.CCM.0000299741.32078.E9

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  28 in total

1.  Preventing ventilator-associated pneumonia: is it ultimately only a matter of gravity?

Authors:  Ioannis Pneumatikos
Journal:  Intensive Care Med       Date:  2012-02-18       Impact factor: 17.440

Review 2.  The microbiome and critical illness.

Authors:  Robert P Dickson
Journal:  Lancet Respir Med       Date:  2015-12-12       Impact factor: 30.700

Review 3.  [Ventilator-associated pneumonia].

Authors:  R Dembinski; R Rossaint
Journal:  Anaesthesist       Date:  2008-08       Impact factor: 1.041

4.  Mechanical influences on fluid leakage past the tracheal tube cuff in a benchtop model.

Authors:  Islem Ouanes; Aissam Lyazidi; Pierre Eric Danin; Nerlep Rana; Annalisa Di Bari; Fekri Abroug; Bruno Louis; Laurent Brochard
Journal:  Intensive Care Med       Date:  2011-02-12       Impact factor: 17.440

Review 5.  Novel preventive strategies for ventilator-associated pneumonia.

Authors:  Andrea Coppadoro; Edward Bittner; Lorenzo Berra
Journal:  Crit Care       Date:  2012-12-12       Impact factor: 9.097

Review 6.  Backrest position in prevention of pressure ulcers and ventilator-associated pneumonia: conflicting recommendations.

Authors:  Ruth Srednicki Burk; Mary Jo Grap
Journal:  Heart Lung       Date:  2012-07-21       Impact factor: 2.210

7.  Randomized, multicenter trial of lateral Trendelenburg versus semirecumbent body position for the prevention of ventilator-associated pneumonia.

Authors:  Gianluigi Li Bassi; Mauro Panigada; Otavio T Ranzani; Alberto Zanella; Lorenzo Berra; Massimo Cressoni; Vieri Parrini; Hassan Kandil; Giovanni Salati; Paola Selvaggi; Alessandro Amatu; Miquel Sanz-Moncosi; Emanuela Biagioni; Fernanda Tagliaferri; Mirella Furia; Giovanna Mercurio; Antonietta Costa; Tullio Manca; Simone Lindau; Jaksa Babel; Marco Cavana; Chiara Chiurazzi; Joan-Daniel Marti; Dario Consonni; Luciano Gattinoni; Antonio Pesenti; Janine Wiener-Kronish; Cecilia Bruschi; Andrea Ballotta; Pierpaolo Salsi; Sergio Livigni; Giorgio Iotti; Javier Fernandez; Massimo Girardis; Maria Barbagallo; Gabriella Moise; Massimo Antonelli; Maria Luisa Caspani; Antonella Vezzani; Patrick Meybohm; Vladimir Gasparovic; Edoardo Geat; Marcelo Amato; Michael Niederman; Theodor Kolobow; Antoni Torres
Journal:  Intensive Care Med       Date:  2017-06-20       Impact factor: 17.440

Review 8.  Efficacy of prone position in acute respiratory distress syndrome patients: A pathophysiology-based review.

Authors:  Vasilios Koulouras; Georgios Papathanakos; Athanasios Papathanasiou; Georgios Nakos
Journal:  World J Crit Care Med       Date:  2016-05-04

9.  Effects of tracheal orientation on development of ventilator-associated pneumonia: an experimental study.

Authors:  Alberto Zanella; Massimo Cressoni; Myra Epp; Viktoria Hoffmann; Mario Stylianou; Theodor Kolobow
Journal:  Intensive Care Med       Date:  2012-02-18       Impact factor: 17.440

10.  Ventilator-associated pneumonia prevention: one good turn does not always deserve another.

Authors:  Pedro Póvoa; Thiago Lisboa; José-Artur Paiva
Journal:  Intensive Care Med       Date:  2017-09-22       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.