Harold Smulyan1, Paul R Sheehe, Michel E Safar. 1. Department of Medicine, Upstate Medical University, State University of New York, Syracuse, New York, USA. smulyanh@upstate.edu
Abstract
BACKGROUND: The brachial artery (BA) mean blood pressure (MBP) is now readily available using the oscillometric technique. In contrast to the auscultatory method where MBP is calculated from the systolic (SBP) and diastolic blood pressure (DBP), oscillometric MBP is measured separately from either SBP or DBP. Because the peripheral MBP is free of amplification, it is nearly the same throughout the entire arterial tree and could represent the corresponding aortic pressure. The oscillometric brachial MBP could therefore serve as a surrogate for aortic MBP and might be a valuable non-invasive risk predictor. METHODS: This study compares the oscillometric BA pressures with simultaneously and directly recorded aortic pressures in 100 patients. RESULTS: These results show that, over a wide range of cuff pressures, the oscillometric MBP, whether alone or with age in multiple regression, predicts aortic pressure better than the SBP or DBP do, with a better correlation coefficient (r = +0.91), low aortic-cuff MBP difference (-0.79 mm Hg) and the lowest s.d. of the individual differences (+7.2 mm Hg). CONCLUSIONS: These results are preliminary and need to be confirmed by larger studies. If confirmed, the predicted aortic pressures should be calculated and displayed by the oscillometric BP devices, the goal being to develop better non-invasive cardiovascular (CV) risk predictors.
BACKGROUND: The brachial artery (BA) mean blood pressure (MBP) is now readily available using the oscillometric technique. In contrast to the auscultatory method where MBP is calculated from the systolic (SBP) and diastolic blood pressure (DBP), oscillometric MBP is measured separately from either SBP or DBP. Because the peripheral MBP is free of amplification, it is nearly the same throughout the entire arterial tree and could represent the corresponding aortic pressure. The oscillometric brachial MBP could therefore serve as a surrogate for aortic MBP and might be a valuable non-invasive risk predictor. METHODS: This study compares the oscillometric BA pressures with simultaneously and directly recorded aortic pressures in 100 patients. RESULTS: These results show that, over a wide range of cuff pressures, the oscillometric MBP, whether alone or with age in multiple regression, predicts aortic pressure better than the SBP or DBP do, with a better correlation coefficient (r = +0.91), low aortic-cuff MBP difference (-0.79 mm Hg) and the lowest s.d. of the individual differences (+7.2 mm Hg). CONCLUSIONS: These results are preliminary and need to be confirmed by larger studies. If confirmed, the predicted aortic pressures should be calculated and displayed by the oscillometric BP devices, the goal being to develop better non-invasive cardiovascular (CV) risk predictors.
Authors: Agustina Zinoveev; Juan M Castro; Victoria García-Espinosa; Mariana Marin; Pedro Chiesa; Daniel Bia; Yanina Zócalo Journal: PLoS One Date: 2019-12-19 Impact factor: 3.240
Authors: Thomas Weber; Athanase D Protogerou; Mohsen Agharazii; Antonis Argyris; Sola Aoun Bahous; Jose R Banegas; Ronald K Binder; Jacques Blacher; Andréa Araujo Brandao; Juan J Cruz; Kathrin Danninger; Cristina Giannatasio; Auxiliadora Graciani; Bernhard Hametner; Piotr Jankowski; Yan Li; Alessandro Maloberti; Christopher C Mayer; Barry J McDonnell; Carmel M McEniery; Marco Antonio Mota Gomes; Annelise Machado Gomes; Maria Lorenza Muiesan; Janos Nemcsik; Anna Paini; Enrique Rodilla; Aletta E Schutte; Petros P Sfikakis; Dimitrios Terentes-Printzios; Alexandre Vallée; Charalambos Vlachopoulos; Lisa Ware; Ian Wilkinson; Robert Zweiker; James E Sharman; Siegfried Wassertheurer Journal: Hypertension Date: 2021-11-15 Impact factor: 10.190
Authors: James E Sharman; Alberto P Avolio; Johannes Baulmann; Athanase Benetos; Jacques Blacher; C Leigh Blizzard; Pierre Boutouyrie; Chen-Huan Chen; Phil Chowienczyk; John R Cockcroft; J Kennedy Cruickshank; Isabel Ferreira; Lorenzo Ghiadoni; Alun Hughes; Piotr Jankowski; Stephane Laurent; Barry J McDonnell; Carmel McEniery; Sandrine C Millasseau; Theodoros G Papaioannou; Gianfranco Parati; Jeong Bae Park; Athanase D Protogerou; Mary J Roman; Giuseppe Schillaci; Patrick Segers; George S Stergiou; Hirofumi Tomiyama; Raymond R Townsend; Luc M Van Bortel; Jiguang Wang; Siegfried Wassertheurer; Thomas Weber; Ian B Wilkinson; Charalambos Vlachopoulos Journal: Eur Heart J Date: 2017-10-01 Impact factor: 29.983