Literature DB >> 18173407

Relationship between second-generation frequency doubling technology and standard automated perimetry in patients with glaucoma.

Andrea Zarkovic1, Justin Mora, James McKelvie, Greg Gamble.   

Abstract

PURPOSE: The aim of the study was to establish the correlation between visual filed loss as shown by second-generation Frequency Doubling Technology (Humphrey Matrix) and Standard Automated Perimetry (Humphrey Field Analyser) in patients with glaucoma. Also, compared were the test duration and reliability.
METHODS: Forty right eyes from glaucoma patients from a private ophthalmology practice were included in this prospective study. All participants had tests within an 8-month period. Pattern deviation plots and mean deviation were compared to establish the correlation between the two perimetry tests. Overall correlation and correlation between hemifields, quadrants and individual test locations were assessed.
RESULTS: Humphrey Field Analyser tests were slightly more reliable (37/40 vs. 34/40 for Matrix)) but overall of longer duration. There was good correlation (0.69) between mean deviations. Superior hemifields and superonasal quadrants had the highest correlation (0.88 [95% CI 0.79, 0.94]). Correlation between individual points was independent of distance from the macula.
CONCLUSION: Generally, the Matrix and Humphrey Field Analyser perimetry correlate well; however, each machine utilizes a different method of analysing data and thus the direct comparison should be made with caution.

Entities:  

Mesh:

Year:  2007        PMID: 18173407     DOI: 10.1111/j.1442-9071.2007.01629.x

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  4 in total

1.  Responses of primate retinal ganglion cells to perimetric stimuli.

Authors:  William H Swanson; Hao Sun; Barry B Lee; Dingcai Cao
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-02-09       Impact factor: 4.799

Review 2.  [Frequency-doubling technology : A new method for determining glaucomatous visual field defects].

Authors:  J Lamparter; A Schulze; E M Hoffmann
Journal:  Ophthalmologe       Date:  2009-08       Impact factor: 1.059

3.  Standard automated perimetry versus matrix frequency doubling technology perimetry in subjects with ocular hypertension and healthy control subjects.

Authors:  Julia Lamparter; Shakhsanam Aliyeva; Andreas Schulze; Manfred Berres; Norbert Pfeiffer; Esther M Hoffmann
Journal:  PLoS One       Date:  2013-02-28       Impact factor: 3.240

4.  Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children.

Authors:  Sibel Kocabeyoglu; Salih Uzun; Mehmet Cem Mocan; Banu Bozkurt; Murat Irkec; Mehmet Orhan
Journal:  Indian J Ophthalmol       Date:  2013-10       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.