Literature DB >> 18173249

Controlling data quality and reproducibility of a high-sensitivity immunoassay using isotachophoresis in a microchip.

C Charles Park1, Irina Kazakova, Tomohisa Kawabata, Michael Spaid, Ring-Ling Chien, H Garrett Wada, Shinji Satomura.   

Abstract

This report describes a method of controlling the sensitivity and reproducibility of a microchip-based immunoassay by using isotachophoresis to preconcentrate the antigen and antibody prior to binding. Gel electrophoresis separation is coupled to the preconcentration step to separate the immunocomplex products formed. The system employs a quartz-based LabChip that automates the metering, preconcentration, reaction, separation, and detection. The system also uses a handoff mechanism that switches the immunocomplex from the stacking mode to the separation mode. We show that the handoff timing affects the data quality and repeatability of the electropherograms, and we demonstrate an automatic handoff mechanism to precisely control the signal intensity and separation of peaks of interest. In so doing, the automatic handoff mechanism also improves the reproducibility of the assay. When applied to the homogeneous liquid-phase detection of alpha-fetoprotein, a common tumor marker, the system shows a greater than 200-fold stacking of specific analytes of interest.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18173249     DOI: 10.1021/ac701709n

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

Review 1.  Advances in microfluidic materials, functions, integration, and applications.

Authors:  Pamela N Nge; Chad I Rogers; Adam T Woolley
Journal:  Chem Rev       Date:  2013-02-14       Impact factor: 60.622

Review 2.  Isotachophoresis: Theory and Microfluidic Applications.

Authors:  Ashwin Ramachandran; Juan G Santiago
Journal:  Chem Rev       Date:  2022-06-22       Impact factor: 72.087

3.  An Automated Micro-Total Immunoassay System for Measuring Cancer-Associated α2,3-linked Sialyl N-Glycan-Carrying Prostate-Specific Antigen May Improve the Accuracy of Prostate Cancer Diagnosis.

Authors:  Tomokazu Ishikawa; Tohru Yoneyama; Yuki Tobisawa; Shingo Hatakeyama; Tatsuo Kurosawa; Kenji Nakamura; Shintaro Narita; Koji Mitsuzuka; Wilhelmina Duivenvoorden; Jehonathan H Pinthus; Yasuhiro Hashimoto; Takuya Koie; Tomonori Habuchi; Yoichi Arai; Chikara Ohyama
Journal:  Int J Mol Sci       Date:  2017-02-22       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.