Literature DB >> 1817209

Computationally two-dimensional finite-difference model for hollow-fibre blood-gas exchange devices.

D A Baker1, J E Holte, S V Patankar.   

Abstract

The goal of this research is to develop a predictive model with good absolute accuracy for blood-gas exchange devices. The proposed model, unlike existing models, is able to predict gas transfer to blood flowing outside oxygenating fibres without experimental data. The proposed model uses a finite-difference numerical technique to solve computationally two-dimensional gas exchange problems such as gas transfer to blood outside hollow fibres. The model is compared to bovine and human experimental data from the small test cells with microporous polypropylene fibres. The test cell flow rates range from 1 m litre min-1 to 5 m litre min-1 for a 72-fibre device. Shear-augmented oxygen diffusion appears to be present, although good accuracy is obtained with a nonaugmented diffusion model, particularly at lower flows. The maximum deviation of oxygen saturation predicted by a shear-augmented bovine blood model from the experimental regression line was 1.7 per cent.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1817209     DOI: 10.1007/BF02442318

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  22 in total

1.  Artificial lung design: tubular membrane units.

Authors:  L F Mockros; J D Gaylor
Journal:  Med Biol Eng       Date:  1975-03

2.  Factors influencing oxygen uptake by blood in membrane oxygenators: report of a study.

Authors:  T I MARX; B R BALDWIN; D R MILLER
Journal:  Ann Surg       Date:  1962-08       Impact factor: 12.969

3.  Predictive correlation of oxygen and carbon dioxide transfer in a blood oxygenator with induced secondary flows.

Authors:  J A Benn; P A Drinker; B Mikic; M C Shults; E J Lacava; G S Kopf; R H Bartlett; E L Hanson
Journal:  Trans Am Soc Artif Intern Organs       Date:  1971

4.  Oxygen transfer to blood: data and theory.

Authors:  W J Dorson; K G Larsen; R J Elgas; M E Voorhees
Journal:  Trans Am Soc Artif Intern Organs       Date:  1971

5.  The use of mathematical and physical models for optimization of oxygenators.

Authors:  A Lautier; R Grossin; D Laurent
Journal:  Trans Am Soc Artif Intern Organs       Date:  1971

6.  The regulation of hemoglobin affinity for oxygen in man.

Authors:  C Lenfant; J D Torrance; C A Finch
Journal:  Trans Assoc Am Physicians       Date:  1969

7.  The capillary membrane blood oxygenator: in vitro and in vivo gas exchange measurements.

Authors:  R P De Filippi; F C Tompkins; J H Porter; R S Timmins; M J Buckley
Journal:  Trans Am Soc Artif Intern Organs       Date:  1968

8.  The third generation of membrane oxygenators: evolution of concepts.

Authors:  A Lautier; T Dehe; T Goda; D Laurent
Journal:  Life Support Syst       Date:  1985

9.  Solute transport induced by erythrocyte motions in shear flow.

Authors:  N H Wang; K H Keller
Journal:  Trans Am Soc Artif Intern Organs       Date:  1979

10.  Compact cross-flow tubular oxygenators.

Authors:  L F Mockros; R Leonard
Journal:  Trans Am Soc Artif Intern Organs       Date:  1985
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.