The elasticity of human oocytes has been estimated by means of a very simple SU-8 microsystem. The device consists of a double SU-8 layer spin coated on a silicon wafer. A micro-beam is patterned by standard photolithography. The silicon wafer is back etched using deep reactive ion etching (DRIE) in order to release the micro-beam. Because the SU-8 resin exhibits a very low Young modulus, beams with stiffnesses of 12 N/m have been easily fabricated. Although the stiffness is not as low as that of Atomic Force Microscopes cantilevers, it was possible to estimate the "deformation-load" characteristics of a few oocytes. A "flattening parameter" of the oocytes is proposed as a function of the applied load and experimental values range from 0.86 microm(2)/Pa to 3.4 microm(2)/Pa for the oocytes under test. Note that this paper belongs to the very few communications concerning the mechanical behaviour of human oocytes.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18165902     DOI: 10.1007/s10544-007-9150-7

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  5 in total

Review 1.  Microfluidic analysis of oocyte and embryo biomechanical properties to improve outcomes in assisted reproductive technologies.

Authors:  Livia Z Yanez; David B Camarillo
Journal:  Mol Hum Reprod       Date:  2017-04-01       Impact factor: 4.025

Review 2.  Microfluidic Systems for Assisted Reproductive Technologies: Advantages and Potential Applications.

Authors:  Russel C Sequeira; Tracy Criswell; Anthony Atala; James J Yoo
Journal:  Tissue Eng Regen Med       Date:  2020-11-25       Impact factor: 4.169

3.  Microfluidic method of pig oocyte quality assessment in relation to different follicular size based on lab-on-chip technology.

Authors:  Bartosz Kempisty; Rafał Walczak; Paweł Antosik; Patrycja Sniadek; Marta Rybska; Hanna Piotrowska; Dorota Bukowska; Jan Dziuban; Michał Nowicki; Jędrzej M Jaśkowski; Maciej Zabel; Klaus-Peter Brüssow
Journal:  Biomed Res Int       Date:  2014-06-09       Impact factor: 3.411

4.  Zona pellucida shear modulus, a possible novel non-invasive method to assist in embryo selection during in-vitro fertilization treatment.

Authors:  Elad Priel; Tsvia Priel; Irit Szaingurten-Solodkin; Tamar Wainstock; Yuval Perets; Atif Zeadna; Avi Harlev; Eitan Lunenfeld; Eliahu Levitas; Iris Har-Vardi
Journal:  Sci Rep       Date:  2020-08-21       Impact factor: 4.379

5.  Visco- and poroelastic contributions of the zona pellucida to the mechanical response of oocytes.

Authors:  Alberto Stracuzzi; Johannes Dittmann; Markus Böl; Alexander E Ehret
Journal:  Biomech Model Mechanobiol       Date:  2021-02-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.