Literature DB >> 18165092

Corneal diameter measurements by corneal topography and angle-to-angle measurements by optical coherence tomography: evaluation of equivalence.

David P Piñero1, Ana Belén Plaza Puche, Jorge L Alió.   

Abstract

PURPOSE: To determine the equivalence of corneal white-to-white (WTW) diameter and anterior segment angle-to-angle (ATA) measurements.
SETTING: Vissum Instituto Oftalmologico de Alicante, Alicante, Spain.
METHODS: Thirty eyes of 19 patients ranging in age from 20 to 51 years old with no previous ocular surgeries were included in this study. In all cases, the horizontal WTW diameter was measured with a tool provided by the CSO corneal topography system (Costruzione Strumenti Oftalmici) and the horizontal ATA was measured using an optical coherence tomography (OCT) system (Visante, Carl Zeiss Meditec AG). All measurements were repeated 3 times to evaluate intrasession repeatability. The correlation between WTW and ATA measurements was studied, and the interchangeability of the 2 parameters was assessed using the Bland and Altman method.
RESULTS: The mean corneal WTW diameter was 12.25 mm +/- 0.49 (SD) (range 11.34 to 13.16 mm), and the mean ATA distance was 11.76 +/- 0.52 mm (range 10.03 to 12.92 mm). The difference between the 2 parameters was statistically significant (P<.01). A weak, although statistically significant, positive correlation (r = 0.39; P = .03) and a nonpredictive linear model were found. The Bland and Altman analysis showed large limits of agreement between WTW and ATA measurements that are clinically relevant (limits of agreement, -1.59 mm and 0.61 mm). The intrasession repeatability scores for the WTW and ATA measurements were good.
CONCLUSIONS: The WTW and ATA distance measurements were not equivalent and thus are not interchangeable. There was no linear model for an accurate prediction of the ATA from the WTW.

Entities:  

Mesh:

Year:  2008        PMID: 18165092     DOI: 10.1016/j.jcrs.2007.10.010

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  17 in total

1.  Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence reflectometer.

Authors:  Mirjana Bjeloš Rončević; Mladen Bušić; Ivan Cima; Biljana Kuzmanović Elabjer; Damir Bosnar; Daliborka Miletić
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-10-28       Impact factor: 3.117

2.  Microstructure-based numerical simulation of the mechanical behaviour of ocular tissue.

Authors:  Dong Zhou; Ahmed Abass; Ashkan Eliasy; Harald P Studer; Alexander Movchan; Natalia Movchan; Ahmed Elsheikh
Journal:  J R Soc Interface       Date:  2019-05-31       Impact factor: 4.118

Review 3.  The posterior chamber phakic refractive lens (PRL): a review.

Authors:  R J Pérez-Cambrodí; D P Piñero; T Ferrer-Blasco; A Cerviño; R Brautaset
Journal:  Eye (Lond)       Date:  2012-12-07       Impact factor: 3.775

4.  Repeatability assessment of anterior segment biometric measurements under accommodative and nonaccommodative conditions using an anterior segment OCT.

Authors:  Noelia Martínez-Albert; Jose J Esteve-Taboada; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-11-02       Impact factor: 3.117

5.  Angle-to-angle and spur-to-spur distance analysis with high-resolution optical coherence tomography.

Authors:  Robert Montés-Micó; Pedro Tañá-Rivero; Salvador Aguilar-Córcoles; María Ruiz-Santos; María Dolores Rodríguez-Carrillo; Ramón Ruiz-Mesa
Journal:  Eye Vis (Lond)       Date:  2020-08-16

6.  Comparison of Eyemetrics and Orbscan automated method to determine horizontal corneal diameter.

Authors:  Arvind Venkataraman; Sapna K Mardi; Sarita Pillai
Journal:  Indian J Ophthalmol       Date:  2010 May-Jun       Impact factor: 1.848

7.  White-to-white corneal diameter distribution in an adult population.

Authors:  Hassan Hashemi; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Abbasali Yekta; Akbar Fotouhi
Journal:  J Curr Ophthalmol       Date:  2015-10-19

8.  In Vivo Evaluation of the Limbus Using Anterior Segment Optical Coherence Tomography.

Authors:  Qihua Le; Daniel Cordova; Jianjiang Xu; Sophie X Deng
Journal:  Transl Vis Sci Technol       Date:  2018-08-07       Impact factor: 3.283

9.  Study of distribution of white-to-white corneal diameter and anterior chamber depth in study population obtained with optical biometry using intraocular lens (IOL) master.

Authors:  Kritika Singh; Sandeep Gupta; P S Moulick; Neeraj Bhargava; Alok Sati; Gagandeep Kaur
Journal:  Med J Armed Forces India       Date:  2018-08-14

10.  Anterior segment ultrasound biomicroscopy image analysis using ImageJ software: Intra-observer repeatability and inter-observer agreement.

Authors:  Azam Qureshi; Haoxing Chen; Osamah Saeedi; Mona A Kaleem; Gianna Stoleru; Jordan Margo; Sachin Kalarn; Janet L Alexander
Journal:  Int Ophthalmol       Date:  2018-03-07       Impact factor: 2.031

View more