Literature DB >> 18165046

Technical and histologic analysis of a retrieved carbon fiber-reinforced poly-ether-ether-ketone composite alumina-bearing liner 28 months after implantation.

Nicola Pace1, Mario Marinelli, Stefania Spurio.   

Abstract

A new innovative low-wear bearing for use in total hip arthroplasty, a wear couple consisting of carbon fiber-reinforced poly-ether-ether-ketone (CF-PEEK), has been shown to be highly biocompatible and to have excellent tribological performance in the laboratory. We report the results of our technical and histologic analysis of a CF-PEEK composite acetabular cup component articulating against an alumina-head total hip arthroplasty prosthesis retrieved because of posttrauma infection from a patient in whom the components had been in place for 28 months. Histologic findings showed only a small amount of particles from the composite insert in the patient's periprosthetic tissue. Additional clinical study is necessary to estimate the relevant in vivo wear performance of CF-PEEK liners.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18165046     DOI: 10.1016/j.arth.2006.07.012

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  12 in total

Review 1.  A guide to assessing post-operative complications following en bloc spinal resection.

Authors:  E Smith; G Hegde; M Czyz; M Grainger; S L James; R Botchu
Journal:  J Clin Orthop Trauma       Date:  2021-10-16

Review 2.  The Use of Carbon-Fiber-Reinforced (CFR) PEEK Material in Orthopedic Implants: A Systematic Review.

Authors:  Chuan Silvia Li; Christopher Vannabouathong; Sheila Sprague; Mohit Bhandari
Journal:  Clin Med Insights Arthritis Musculoskelet Disord       Date:  2015-02-23

Review 3.  The Biologic Response to Polyetheretherketone (PEEK) Wear Particles in Total Joint Replacement: A Systematic Review.

Authors:  Ashley A Stratton-Powell; Kinga M Pasko; Claire L Brockett; Joanne L Tipper
Journal:  Clin Orthop Relat Res       Date:  2016-07-18       Impact factor: 4.176

4.  Analysis of Carbon Fiber Reinforced PEEK Hinge Mechanism Articulation Components in a Rotating Hinge Knee Design: A Comparison of In Vitro and Retrieval Findings.

Authors:  Ronja A Schierjott; Alexander Giurea; Hans-Joachim Neuhaus; Jens Schwiesau; Andreas M Pfaff; Sandra Utzschneider; Gianluca Tozzi; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2016-12-22       Impact factor: 3.411

5.  Rapid Analyses of Polyetheretherketone Wear Characteristics by Accelerated Wear Testing with Microfabricated Surfaces for Artificial Joint Systems.

Authors:  Chen-Ying Su; Chien-Wei Kuo; Hsu-Wei Fang
Journal:  Biomed Res Int       Date:  2017-11-02       Impact factor: 3.411

6.  Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study.

Authors:  Joost J A de Jong; Arno Lataster; Bert van Rietbergen; Jacobus J Arts; Piet P Geusens; Joop P W van den Bergh; Paul C Willems
Journal:  BMC Med Imaging       Date:  2017-02-27       Impact factor: 1.930

7.  PEEK‑biphasic bioceramic composites promote mandibular defect repair and upregulate BMP‑2 expression in rabbits.

Authors:  Hedong Yu; Yongji Chen; Min Mao; Dongyan Liu; Jun Ai; Weidong Leng
Journal:  Mol Med Rep       Date:  2018-04-11       Impact factor: 2.952

8.  Mechanical properties of highly porous PEEK bionanocomposites incorporated with carbon and hydroxyapatite nanoparticles for scaffold applications.

Authors:  Md Nizam Uddin; Puttagounder S Dhanasekaran; Ramazan Asmatulu
Journal:  Prog Biomater       Date:  2019-10-19

9.  Influence of the Surface Roughness of PEEK GRF30 and Ti6Al4V SLM on the Viability of Primary Human Osteoblasts Determined by the MTT Test.

Authors:  Piotr Prochor; Żaneta Anna Mierzejewska
Journal:  Materials (Basel)       Date:  2019-12-13       Impact factor: 3.623

10.  Early results of a new rotating hinge knee implant.

Authors:  Alexander Giurea; Hans-Joachim Neuhaus; Rolf Miehlke; Reinhard Schuh; Richard Lass; Bernd Kubista; Reinhard Windhager
Journal:  Biomed Res Int       Date:  2014-06-25       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.