Three-dimensional intrafractional motion of breast during tangential breast irradiation monitored with high-sampling frequency using a real-time tumor-tracking radiotherapy system.

Rumiko Kinoshita1, Shinichi Shimizu, Hiroshi Taguchi, Norio Katoh, Masaharu Fujino, Rikiya Onimaru, Hidefumi Aoyama, Fumi Katoh, Tokuhiko Omatsu, Masayori Ishikawa, Hiroki Shirato.   

Abstract

PURPOSE: To evaluate the three-dimensional intrafraction motion of the breast during tangential breast irradiation using a real-time tracking radiotherapy (RT) system with a high-sampling frequency. METHODS AND MATERIALS: A total of 17 patients with breast cancer who had received breast conservation RT were included in this study. A 2.0-mm gold marker was placed on the skin near the nipple of the breast for RT. A fluoroscopic real-time tumor-tracking RT system was used to monitor the marker. The range of motion of each patient was calculated in three directions.
RESULTS: The mean +/- standard deviation of the range of respiratory motion was 1.0 +/- 0.6 mm (median, 0.9; 95% confidence interval [CI] of the marker position, 0.4-2.6), 1.3 +/- 0.5 mm (median, 1.1; 95% CI, 0.5-2.5), and 2.6 +/- 1.4 (median, 2.3; 95% CI, 1.0-6.9) for the right-left, craniocaudal, and anteroposterior direction, respectively. No correlation was found between the range of motion and the body mass index or respiratory function. The mean +/- standard deviation of the absolute value of the baseline shift in the right-left, craniocaudal, and anteroposterior direction was 0.2 +/- 0.2 mm (range, 0.0-0.8 mm), 0.3 +/- 0.2 mm (range, 0.0-0.7 mm), and 0.8 +/- 0.7 mm (range, 0.1-1.8 mm), respectively.
CONCLUSION: Both the range of motion and the baseline shift were within a few millimeters in each direction. As long as the conventional wedge-pair technique and the proper immobilization are used, the intrafraction three-dimensional change in the breast surface did not much influence the dose distribution.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18164868     DOI: 10.1016/j.ijrobp.2007.10.003

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  24 in total

1.  Erratum to: Molecular and cellular mechanisms that initiate pain and itch.

Authors:  Jialie Luo; Jing Feng; Shenbin Liu; Edgar T Walters; Hongzhen Hu
Journal:  Cell Mol Life Sci       Date:  2015-09       Impact factor: 9.261

2.  Treatment planning study of Volumetric Modulated Arc Therapy and three dimensional field-in-field techniques for left chest-wall cancers with regional lymph nodes.

Authors:  Heping Xu; Gillian Hatcher
Journal:  Rep Pract Oncol Radiother       Date:  2016-08-24

3.  Nonisocentric treatment strategy for breast radiation therapy: a proof of concept study.

Authors:  Ruijiang Li; Lei Xing; Kathleen C Horst; Karl Bush
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-03-15       Impact factor: 7.038

4.  Hybrid volumetric modulated arc therapy for whole breast irradiation: a dosimetric comparison of different arc designs.

Authors:  Velayudham Ramasubramanian; Karunakaran Balaji; Sitaraman Balaji Subramanian; Krishnamoorthi Sathiya; Moorthi Thirunavukarasu; Chandrasekaran Anu Radha
Journal:  Radiol Med       Date:  2019-01-30       Impact factor: 3.469

5.  Effect of breathing motion in radiotherapy of breast cancer: 4D dose calculation and motion tracking via EPID.

Authors:  Anne Richter; Reinhard Sweeney; Kurt Baier; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2009-08-28       Impact factor: 3.621

6.  Surface dose in the treatment of breast cancer with helical tomotherapy.

Authors:  Felix Zibold; Florian Sterzing; Gabriele Sroka-Perez; Kai Schubert; Katja Wagenknecht; Gerald Major; Jürgen Debus; Klaus Herfarth
Journal:  Strahlenther Onkol       Date:  2009-09-12       Impact factor: 3.621

7.  Dosimetric comparison between intensity-modulated radiotherapy and standard wedged tangential technique for whole-breast radiotherapy in Asian women with relatively small breast volumes.

Authors:  Kazuhiko Tsuchiya; Rumiko Kinoshita; Shinichi Shimizu; Kentaro Nishioka; Keiichi Harada; Noboru Nishikawa; Ryusuke Suzuki; Hiroki Shirato
Journal:  Radiol Phys Technol       Date:  2013-08-28

8.  Hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities.

Authors:  Yoshiko Doi; Minoru Nakao; Hideharu Miura; Shuichi Ozawa; Masahiro Kenjo; Yasushi Nagata
Journal:  J Radiat Res       Date:  2020-09-08       Impact factor: 2.724

9.  Reduction of motion artefacts in on-board cone beam CT by warping of projection images.

Authors:  T E Marchant; G J Price; B J Matuszewski; C J Moore
Journal:  Br J Radiol       Date:  2010-11-16       Impact factor: 3.039

10.  Different intensity extension methods and their impact on entrance dose in breast radiotherapy: A study.

Authors:  A Sankar; J Velmurugan
Journal:  J Med Phys       Date:  2009-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.