Literature DB >> 18164834

Projector-based augmented reality for intuitive intraoperative guidance in image-guided 3D interstitial brachytherapy.

Robert Krempien1, Harald Hoppe, Lüder Kahrs, Sascha Daeuber, Oliver Schorr, Georg Eggers, Marc Bischof, Marc W Munter, Juergen Debus, Wolfgang Harms.   

Abstract

PURPOSE: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. METHODS AND MATERIALS: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient.
RESULTS: In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm).
CONCLUSIONS: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.

Entities:  

Mesh:

Year:  2007        PMID: 18164834     DOI: 10.1016/j.ijrobp.2007.10.048

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  13 in total

1.  Illustrative visualization of 3D planning models for augmented reality in liver surgery.

Authors:  Christian Hansen; Jan Wieferich; Felix Ritter; Christian Rieder; Heinz-Otto Peitgen
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-06-19       Impact factor: 2.924

2.  A surgical robot with augmented reality visualization for stereoelectroencephalography electrode implantation.

Authors:  Bowei Zeng; Fanle Meng; Hui Ding; Guangzhi Wang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-29       Impact factor: 2.924

Review 3.  A review of recent developments in image-guided radiation therapy in cervix cancer.

Authors:  Azmat H Sadozye; Nicholas Reed
Journal:  Curr Oncol Rep       Date:  2012-12       Impact factor: 5.075

4.  Projection-based visual guidance for robot-aided RF needle insertion.

Authors:  Rong Wen; Chee-Kong Chui; Sim-Heng Ong; Kah-Bin Lim; Stephen Kin-Yong Chang
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-05-07       Impact factor: 2.924

5.  Intraoperative application of hand-held structured light scanning: a feasibility study.

Authors:  Brandon Chan; Jason Auyeung; John F Rudan; Randy E Ellis; Manuela Kunz
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-26       Impact factor: 2.924

6.  Stereotactic co-axial projection imaging for augmented reality neuronavigation: a proof-of-concept study.

Authors:  Bingxuan Wu; Peng Liu; Chi Xiong; Chenmeng Li; Fan Zhang; Shuwei Shen; Pengfei Shao; Peng Yao; Chaoshi Niu; Ronald Xu
Journal:  Quant Imaging Med Surg       Date:  2022-07

7.  Image Overlay Surgery Based on Augmented Reality: A Systematic Review.

Authors:  Laura Pérez-Pachón; Matthieu Poyade; Terry Lowe; Flora Gröning
Journal:  Adv Exp Med Biol       Date:  2020       Impact factor: 2.622

8.  Effect of marker position and size on the registration accuracy of HoloLens in a non-clinical setting with implications for high-precision surgical tasks.

Authors:  Laura Pérez-Pachón; Parivrudh Sharma; Helena Brech; Jenny Gregory; Terry Lowe; Matthieu Poyade; Flora Gröning
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-04-15       Impact factor: 2.924

9.  Real-time in situ three-dimensional integral videography and surgical navigation using augmented reality: a pilot study.

Authors:  Hideyuki Suenaga; Huy Hoang Tran; Hongen Liao; Ken Masamune; Takeyoshi Dohi; Kazuto Hoshi; Yoshiyuki Mori; Tsuyoshi Takato
Journal:  Int J Oral Sci       Date:  2013-05-24       Impact factor: 6.344

10.  Accuracy evaluation of a 3D-printed individual template for needle guidance in head and neck brachytherapy.

Authors:  Ming-Wei Huang; Jian-Guo Zhang; Lei Zheng; Shu-Ming Liu; Guang-Yan Yu
Journal:  J Radiat Res       Date:  2016-07-15       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.