Literature DB >> 18161805

Cumulative effect of disinfection procedures on microhardness and tridimensional stability of a poly(methyl methacrylate) denture base resin.

Evandro Afonso Sartori1, Caroline Bom Schmidt, Eduardo Gonçalves Mota, Luciana Mayumi Hirakata, Rosemary Sadami Arai Shinkai.   

Abstract

Microwave irradiation has been used for disinfection of dentures instead of chemical solutions; yet, its effect on resin properties after repeated procedures still is unclear. This study evaluated the cumulative effect of two disinfection methods on Knoop microhardness and tridimensional stability of a poly(methyl methacrylate) denture base resin. For the microhardness measurement, 24-resin discs received mechanical polishing and were submitted to the following treatments: (1) control (no disinfection), (2) chemical disinfection (immersion in 100ppm chloride solution for 24h), or (3) microwave disinfection (irradiation at 690 W for 6 min). Disinfection procedures were performed twice (T1, T2) with a 7-day interval. Knoop microhardness was recorded after polishing (T0) and after T1 and T2. For the dimensional stability test (measured by the adaptation of the denture bases), 36-maxillary denture bases were obtained from type III dental stone casts duplicated from a metallic master model and submitted to the disinfection treatment. Adaptation of denture bases was measured at baseline (T0) and after T1 and T2 by weighing a vinyl polysiloxane film reproducing the gap between resin base and master model. Data were analyzed by ANOVA GLM for repeated measures and Bonferroni's test, alpha = 0.05. Knoop microhardness was not modified by any disinfection procedure but decreased over time. Denture resin bases submitted to microwave disinfection had gradual increase of distortion over time, while bases immersed in chloride solution did not differ from the control group and remained dimensionally stable from T1 to T2. (c) 2007 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18161805     DOI: 10.1002/jbm.b.31027

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  4 in total

1.  Comparative evaluation of color change between two types of acrylic resin and flexible resin after thermo cycling. An in vitro study.

Authors:  Nadira A Hatim; Omar Zeno Al-Tahho
Journal:  J Indian Prosthodont Soc       Date:  2013-05-05

Review 2.  The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview.

Authors:  Theodoros Klironomos; Aspasia Katsimpali; Gregory Polyzois
Journal:  Acta Stomatol Croat       Date:  2015-09

3.  The Effect of Repeated Microwaving Disinfection on the Dimensional Stability of Acrylic Dentures.

Authors:  Nick Polychronakis; Stavros Yannikakis; Alcibiades Zissis
Journal:  Acta Stomatol Croat       Date:  2014-12

4.  Cumulative effect of microwave sterilization on the physical properties of microwave polymerized and conventional heat-polymerized acrylic resin.

Authors:  S Mohammed Shafeeq; S Karthikeyan; Subash M Reddy; Suma Karthigeyan; R Manikandan; Arthiie Thangavelu
Journal:  J Pharm Bioallied Sci       Date:  2016-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.