Literature DB >> 18161697

Microemulsion electrokinetic chromatography hyphenated to atmospheric pressure photoionization mass spectrometry.

Julie Schappler1, Davy Guillarme, Serge Rudaz, Jean-Luc Veuthey.   

Abstract

CZE is an appropriate technique for separating charged species, but lacks selectivity for neutral compounds. Alternative approaches such as microemulsion electrokinetic chromatography (MEEKC) have been developed to broaden its range of applications. Hyphenation of MEEKC with MS is an attractive perspective since it can enhance sensitivity and selectivity. The on-line coupling of MEEKC with MS, however, is not straightforward due to the low compatibility of non-volatile surfactant additives (e.g. SDS) and the commonly used API source, namely ESI. In order to hyphenate MEEKC with MS detection, the atmospheric pressure photoionization (APPI) source was investigated. Possibilities offered by the coupling of MEEKC with APPI-MS were highlighted for the complex separation of ionized and neutral compounds in both the positive and negative modes. MEEKC-APPI-MS performance, in terms of selectivity, efficiency and sensitivity was compared to CZE-ESI-MS and MEEKC-ESI-MS for the screening of doping substances (beta-blockers, central stimulants, diuretics, etc). Relevant selectivity and detectability, particularly for neutral, structurally related and isobaric compounds was demonstrated with the MEEKC-APPI-MS approach opening new avenues for CE-MS, in addition to the well-established CZE-ESI-MS technique.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18161697     DOI: 10.1002/elps.200700647

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

1.  Chiral micellar electrokinetic chromatography-atmospheric pressure photoionization of benzoin derivatives using mixed molecular micelles.

Authors:  Jun He; Shahab A Shamsi
Journal:  Electrophoresis       Date:  2011-04-18       Impact factor: 3.535

2.  The first example of MEEKC-ICP-MS coupling and its application for the analysis of anticancer platinum complexes.

Authors:  Anna K Bytzek; Michael R Reithofer; Markus Galanski; Michael Groessl; Bernhard K Keppler; Christian G Hartinger
Journal:  Electrophoresis       Date:  2010-04       Impact factor: 3.595

3.  Capillary electrophoresis-atmospheric pressure chemical ionization-mass spectrometry using an orthogonal interface: set-up and system parameters.

Authors:  Paul Hommerson; Amjad M Khan; Gerhardus J de Jong; Govert W Somsen
Journal:  J Am Soc Mass Spectrom       Date:  2009-03-13       Impact factor: 3.109

4.  Multivariate approach for the enantioselective analysis in micellar electrokinetic chromatography-mass spectrometry. I. Simultaneous optimization of binaphthyl derivatives in negative ion mode.

Authors:  Jun He; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2008-12-06       Impact factor: 4.759

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.