Literature DB >> 18158771

Breast cancer axillary lymph node metastasis detection by a high-resolution dedicated breast camera: a comparative study with SPECT and pinhole SPECT.

Angela Spanu1, Francesca Chessa, Daniela Sanna, Pierina Cottu, Alessandra Manca, Susanna Nuvoli, Giuseppe Madeddu.   

Abstract

We evaluated the usefulness of (99m)Tc-tetrofosmin planar scintigraphy acquired with a high-resolution (HR) dedicated breast camera in comparison with conventional single-photon emission computed tomography (SPECT) and pinhole-SPECT (P-SPECT) in breast cancer (BC) axillary lymph node metastasis detection in a consecutive series of 76 BC patients, 28 of whom had axillary lymph node metastases, including 9 positive at clinical examination. HR planar scintigraphy was true positive in only 7 patients with >3 palpable metastases (sensitivity: 25%), while SPECT was true positive in 23 of 28 cases (sensitivity: 82.1%) and P-SPECT in 25 of 28 (sensitivity: 89.3%). SPECT was false negative in 5 patients with nonpalpable <or= 3 nodes, including 2 with one micrometastatic node, while P-SPECT was false negative in the latter 2 cases, and in another of the cases, false negative at SPECT with one macrometastatic node. Neither planar nor SPECT had false-positive findings (specificity: 100%), while P-SPECT had two (specificity: 95.8%). P-SPECT presented the best resolution in showing the metastatic nodes and was the only procedure able to define the number of involved nodes, thus delivering important prognostic information. HR planar scintigraphy appears an ineffective diagnostic tool in BC axillary lymph node metastasis detection, only succeeding in identifying palpable and >3 metastatic nodes. SPECT should be preferred, significantly improving the sensitivity of planar scintigraphy, especially when using a pinhole collimator.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18158771     DOI: 10.1089/cbr.2007.367

Source DB:  PubMed          Journal:  Cancer Biother Radiopharm        ISSN: 1084-9785            Impact factor:   3.099


  4 in total

1.  The importance of standardized interpretation of molecular breast imaging with dedicated gamma cameras.

Authors:  Orazio Schillaci
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-06       Impact factor: 9.236

Review 2.  Clinical usefulness of breast-specific gamma imaging as an adjunct modality to mammography for diagnosis of breast cancer: a systemic review and meta-analysis.

Authors:  Yu Sun; Wei Wei; Hua-Wei Yang; Jian-Lun Liu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-11-14       Impact factor: 9.236

3.  The role of molecular breast imaging in predicting complete tumor response to treatment and residual tumor extent following neoadjuvant therapy.

Authors:  Susanna Nuvoli; Sarah Galassi; Ilaria Gelo; Gaia Rocchitta; Alessandro Fancellu; Pier Andrea Serra; Giuseppe Madeddu; Angela Spanu
Journal:  Oncol Rep       Date:  2018-03-06       Impact factor: 3.906

4.  Comparison of 99mTc-MIBI scintigraphy, ultrasound, and mammography for the diagnosis of BI-RADS 4 category lesions.

Authors:  Hongbiao Liu; Hongwei Zhan; Da Sun
Journal:  BMC Cancer       Date:  2020-05-24       Impact factor: 4.430

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.