Wire-based ureteral stents: impact on tensile strength and compression.

Renato N Pedro1, Kari Hendlin, Carly Kriedberg, Manoj Monga.   

Abstract

OBJECTIVES: To evaluate the performance of coil-based ureteral stents in terms of tensile strength and the radial compression force.
METHODS: Three Cook Resonance (RES) metallic coil stents and three coil-reinforced Applied Medical Silhouette (SIL) ureteral stents were tested. An MTS MicroBionix Testing System using Testworks II software, vibration isolation table, and 5-N load cell were used to measure tensile and compressive strength. Stents were placed in hydraulic grips spaced 24 cm apart and stretched at a rate of 5 mm/s for 1 second under uniaxial tension. Extrinsic compression was exerted in 0.2-mm increments to maximum compression. The Young's modulus, E, was calculated for each trial using the engineering stress. Comparisons were made with the Cook C-flex, which in previous studies was shown to be stiffer and more resistant to compression than other traditional polymer stents.
RESULTS: The RES and SIL stents demonstrated tensile strengths of 936 +/- 485 kPa and 770 +/- 82 kPa, respectively (P = 0.02). The elastic modulus required to cause extrinsic compression was lower for the RES (63,248 +/- 3218 Pa) than for the SIL (105,664 +/- 11,529 Pa) (P <0.001). Both stents were more resistant to stent compression than previously tested stents without coil-reinforcement, the strongest of which was the Cook C-Flex (E = 30,355 +/- 910 Pa; P <0.001).
CONCLUSIONS: Both the Cook Resonance and Applied Medical Silhouette stents are more resistant to extrinsic stent compression than ureteral stents that are not coil-reinforced. The Cook Resonance has a higher tensile strength, whereas the Applied Medical Silhouette is more resistant to extrinsic compression.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18158013     DOI: 10.1016/j.urology.2007.08.007

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  16 in total

1.  Ureteral stents: new ideas, new designs.

Authors:  Abdulrahman Al-Aown; Iason Kyriazis; Panagiotis Kallidonis; Pantelis Kraniotis; Christos Rigopoulos; Dimitrios Karnabatidis; Theodore Petsas; Evangelos Liatsikos
Journal:  Ther Adv Urol       Date:  2010-04

2.  Update on ureteral stent technology.

Authors:  Dirk Lange; Ben H Chew
Journal:  Ther Adv Urol       Date:  2009-08

3.  The first use of Resonance(®) metallic ureteric stent in a case of obstructed transplant kidney.

Authors:  Mohamed I Abdulmajed; Vaughan W Jones; Iqbal S Shergill
Journal:  Int J Surg Case Rep       Date:  2014-04-24

4.  Changing to a loop-type ureteral stent decreases patients' stent-related symptoms.

Authors:  Takashi Kawahara; Hiroki Ito; Hideyuki Terao; Takehiko Ogawa; Hiroji Uemura; Yoshinobu Kubota; Junichi Matsuzaki
Journal:  Urol Res       Date:  2012-08-17

Review 5.  [Management of ureteral obstruction : Value of percutaneous nephrostomy and ureteral stents].

Authors:  C Netsch; B Becker; A J Gross
Journal:  Urologe A       Date:  2016-11       Impact factor: 0.639

Review 6.  Ureteral stent symptoms and associated infections: a biomaterials perspective.

Authors:  Ben H Chew; Dirk Lange
Journal:  Nat Rev Urol       Date:  2009-07-14       Impact factor: 14.432

7.  Metal ureteral stents in chronic obstructions.

Authors:  Daniel Yachia
Journal:  Indian J Urol       Date:  2011-07

Review 8.  The full metallic double-pigtail ureteral stent: Review of the clinical outcome and current status.

Authors:  Panagiotis S Kallidonis; Ioannis S Georgiopoulos; Iason D Kyriazis; Stavros Kontogiannis; Abdulrahman M Al-Aown; Evangelos N Liatsikos
Journal:  Indian J Urol       Date:  2015 Jan-Mar

9.  Physical Properties of Electropolished CoCrMo Alloy Coated with Biodegradable Polymeric Coatings Releasing Heparin after Prolonged Exposure to Artificial Urine.

Authors:  Wojciech Kajzer; Janusz Szewczenko; Anita Kajzer; Marcin Basiaga; Joanna Jaworska; Katarzyna Jelonek; Katarzyna Nowińska; Marcin Kaczmarek; Ada Orłowska
Journal:  Materials (Basel)       Date:  2021-05-14       Impact factor: 3.623

10.  Updates on the use of ureteral stents: focus on the Resonance(®) stent.

Authors:  Manoj V Rao; Anthony J Polcari; Thomas Mt Turk
Journal:  Med Devices (Auckl)       Date:  2010-12-22