Literature DB >> 18156061

A biomechanical evaluation to optimize the configuration of a hinged external fixator for the primary treatment of severely displaced intraarticular calcaneus fractures with soft tissue damage.

Lutz Besch1, Ina Schmidt, Michael Mueller, Mark Daniels-Wredenhagen, Ralf-Eric Hilgert, Deike Varoga, Andreas Seekamp.   

Abstract

The purpose of this investigation was to develop an optimized hinged external fixator for the primary treatment of dislocated, intra-articular calcaneus fractures with associated soft tissue damage. To this end, a calcaneus model was made out of a polyurethane block, and a steel cylinder served as the ankle joint and was connected to a synthetic model of the tibia via a metal clamp. A saw cut served as the fracture in the model. A Steinmann nail and Schanz screw were placed in defined positions in the model and connected medially and laterally with longitudinal support rods. The fixator allowed a total of 20 degrees of plantar- and dorsiflexion, with rotation in the virtual axis of the upper ankle joint. Changes in the model fracture were measured during cyclical strain, and at different screw positions in the model tibia and calcaneus. Miniature force sensors located on the longitudinal support rods, and a plantar tension spring, were used to measure pressure and tension. Reproducible values were determined and, with the optimal configuration, shifting within the osteotomy was minimal. In the experimental configuration, optimal tibial screw placement was 70 mm proximal to the rotation axis of the upper ankle joint, and optimal placement of the Steinmann nail was in the posterior surface of the calcaneus. These findings indicated that the hinged fixator allows 20 degrees of ankle movement without alteration of the rotation axis, and suggest that this type of external fixator can be used in all types of calcaneal fracture regardless of the soft tissue damage. ACFAS Level of Clinical Evidence: 5c.

Entities:  

Mesh:

Year:  2008        PMID: 18156061     DOI: 10.1053/j.jfas.2007.10.014

Source DB:  PubMed          Journal:  J Foot Ankle Surg        ISSN: 1067-2516            Impact factor:   1.286


  4 in total

1.  Could percutaneous fixation with crossed Schanz pins be an alternative to open reduction in the treatment of intra-articular calcaneal fractures?

Authors:  Altuğ Duramaz; Ömer Polat; Mehmet Hakan İlter; Berhan Bayram; Alkan Bayrak; Emre Baca
Journal:  Int Orthop       Date:  2021-01-30       Impact factor: 3.075

2.  Surgical treatment of intra-articular calcaneal fractures: description of a technique using an adjustable uniplanar external fixator.

Authors:  Randal Rudge Ramos; Carlos Daniel Candido de Castro Filho; Roger Rudge Ramos; Cíntia Kelly Bittar; Mario Sérgio Paulilo de Cillo; Carlos Augusto de Mattos; José Luís Amim Zabeu; Antenor Rafael Mazzuia
Journal:  Strategies Trauma Limb Reconstr       Date:  2014-12-25

3.  Comparative study on three surgical techniques for intra-articular calcaneal fractures: open reduction with internal fixation using a plate, external fixation and minimally invasive surgery.

Authors:  Missa Takasaka; Cintia Kelly Bittar; Fernando Saddi Mennucci; Carlos Augusto de Mattos; José Luís Amim Zabeu
Journal:  Rev Bras Ortop       Date:  2016-04-09

Review 4.  An engineering review of external fixators.

Authors:  P L N Fernando; Aravinda Abeygunawardane; Pci Wijesinghe; Parakrama Dharmaratne; Pujitha Silva
Journal:  Med Eng Phys       Date:  2021-11-04       Impact factor: 2.242