Literature DB >> 18154274

Direct coupling of ionic liquid based single-drop microextraction and GC/MS.

Eva Aguilera-Herrador1, Rafael Lucena, Soledad Cardenas, Miguel Valcárcel.   

Abstract

The use of ionic liquids as extracting media in single-drop liquid-phase microextraction (SDME) and its direct coupling to gas chromatography/mass spectrometry (GC/MS) is presented. For this purpose, a new removable interface that enables the introduction of the extracted analytes into the GC system, while preventing the ionic liquid from entering the column, has been developed. The determination of three representative pollutants in water samples has been used as a model analytical problem in order to demonstrate the feasibility of the proposed interface. The analytes (dichloromethane, p-xylene, and n-undecane) were coextracted from the aqueous sample in a 2-microL drop of 1-butyl-3-methylimidazolium hexaflourophosphate. Then, the syringe used to perform the SDME was directly introduced into the interface, which was held at 140 degrees C in order to achieve a complete volatilization of the target compounds. After the injection, the ionic liquid was retained in the interface, while a carrier gas transferred the volatilized analytes into the GC inlet. The optimization of the operational variables affecting the new interface (temperature, carrier flow rate, sample volume and injection technique) was accomplished. The analytes could be determined with detection limits in the low-nanogram per milliliter concentration range, and the relative standard deviations were between 3.3 and 4.4%.

Entities:  

Year:  2007        PMID: 18154274     DOI: 10.1021/ac071555g

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Preconcentration and determination of lead and cadmium levels in blood samples of adolescent workers consuming smokeless tobacco products in Pakistan.

Authors:  Sadaf Sadia Arain; Tasneem Gul Kazi; Hassan Imran Afridi; Kapil Dev Brahman; Sumaira Khan; Abdul Haleem Panhwar; Muhammad Afzal Kamboh; Jamil R Memon
Journal:  Environ Monit Assess       Date:  2015-05-01       Impact factor: 2.513

2.  Development of Surface Molecularly Imprinted Polymers as Dispersive Solid Phase Extraction Coupled with HPLC Method for the Removal and Detection of Griseofulvin in Surface Water.

Authors:  Kamran Bashir; Zhimin Luo; Guoning Chen; Hua Shu; Xia Cui; Wen Li; Wang Lu; Qiang Fu
Journal:  Int J Environ Res Public Health       Date:  2019-12-24       Impact factor: 3.390

3.  Detection of Polycyclic Aromatic Hydrocarbons in Water Samples by Annular Platform-Supported Ionic Liquid-Based Headspace Liquid-Phase Microextraction.

Authors:  Xiaojie Sun; Jie Tan; Haiyan Ding; Xiaojie Tan; Jun Xing; Lihong Xing; Yuxiu Zhai; Zhaoxin Li
Journal:  J Anal Methods Chem       Date:  2018-09-27       Impact factor: 2.193

  3 in total