Abstract

Radiovisiography (RVG) and conventional film (CF) were compared in an in-vitro study for working length estimation of root canals. Hedstrom files (size 15) were placed in the root canals of 60 extracted teeth and the teeth imaged using both CF and RVG. The length of file observed was assessed on CF, RVG and enhanced RVG images. The results indicated that a greater length of file was imaged with CF than with RVG (P less than 0.05). However, enhanced RVG images were not significantly different from CF images. While clinical studies are now indicated to confirm these results, it is suggested that, when utilizing RVG for length estimation in root canal treatment, the enhancement facility should be used.

Mesh:

Year:  1991        PMID: 1813427

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  6 in total

1.  Location and shape of the apical foramina in posterior teeth: an in-vitro analysis.

Authors:  Mohnish Zulfikar Manva; Riyadh Alroomy; Shamama Sheereen; Manoj Kumar Hans; Sreekanth Kumar Mallineni
Journal:  Surg Radiol Anat       Date:  2020-11-16       Impact factor: 1.246

2.  Comparison of the accuracy of conventional and digital radiography in root canal working length determination: An invitro study.

Authors:  Mohammad Mahdi Yaghooti Khorasani; Hamed Ebrahimnejad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-09-20

3.  Assessment of endodontically treated teeth by using different radiographic methods: an ex vivo comparison between CBCT and other radiographic techniques.

Authors:  Kemal Özgür Demiralp; Kıvanç Kamburoğlu; Kahraman Güngör; Selcen Yüksel; Gokcen Demiralp; Ozlem Uçok
Journal:  Imaging Sci Dent       Date:  2012-09-21

4.  Comparison of the delay in processing time and protective plastic cases in two phosphor plate systems.

Authors:  Ali Murat Aktan; Mehmet Ertuğrul Ciftçi; Faruk Akgünlü
Journal:  ScientificWorldJournal       Date:  2012-11-07

5.  Direct digital radiography versus conventional radiography - assessment of visibility of file length placed in the root canal: An in vitro study.

Authors:  Vaiyapuri Ravi; Priyadarshini Lipee; Canagapalli Venkat Nakabushan Rao; Lakshminarayanan Lakshmikanthan
Journal:  J Pharm Bioallied Sci       Date:  2012-08

6.  A comparative assessment of the accuracy of electronic apex locator (Root ZX) in the presence of commonly used irrigating solutions.

Authors:  Osama Khattak; Ebadullah Raidullah; Maria L Francis
Journal:  J Clin Exp Dent       Date:  2014-02-01