Literature DB >> 1813401

The use of titanium fixtures for intraoral anchorage to facilitate orthodontic tooth movement.

K W Higuchi, J M Slack.   

Abstract

The use of endosseous implants to facilitate orthodontic tooth movement has been periodically reported in the scientific literature for over 40 years. The predictable achievement of rigid bone-implant anchorage was first applied by Brånemark in 1965. Using the osseointegration method, a prospective study was conducted involving seven adult patients who were treated with titanium implants used as rigid anchorage units. Orthodontic forces were directed off the implants to correct a variety of malocclusions. All 14 implants placed remained stable during the course of treatment with loading forces of 150 to 400 g. No significant complications occurred. Desirable occlusal and facial results were achieved in all cases. The results obtained over a 3-year period of treatment indicate that intraoral rigid anchorage in the absence of observed reciprocal action is possible.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1813401

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  9 in total

1.  Ball Headed Mini Implant.

Authors:  N Raj Vikram; Ramachandra Prabhakar; S Aravind Kumar; M K Karthikeyan; R Saravanan
Journal:  J Clin Diagn Res       Date:  2017-01-01

2.  Patients' and orthodontists' perceptions of miniplates used for temporary skeletal anchorage: a prospective study.

Authors:  Marie A Cornelis; Nicole R Scheffler; Catherine Nyssen-Behets; Hugo J De Clerck; J F Camilla Tulloch
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-01       Impact factor: 2.650

3.  Osseointegration of orthodontic micro-screws after immediate and early loading.

Authors:  Linkun Zhang; Zhihe Zhao; Yu Li; Jiapei Wu; Leilei Zheng; Tian Tang
Journal:  Angle Orthod       Date:  2010-03       Impact factor: 2.079

4.  Clinical factors correlated with the success rate of miniscrews in orthodontic treatment.

Authors:  Nikolaos Topouzelis; Phoebus Tsaousoglou
Journal:  Int J Oral Sci       Date:  2012-01-12       Impact factor: 6.344

5.  Mini-implants in the anchorage armamentarium: new paradigms in the orthodontics.

Authors:  Masaru Yamaguchi; Toshihiro Inami; Ko Ito; Kazutaka Kasai; Yasuhiro Tanimoto
Journal:  Int J Biomater       Date:  2012-06-05

6.  Peri-implant evaluation of osseointegrated implants subjected to orthodontic forces: results after three years of functional loading.

Authors:  Bruna de Rezende Marins; Suy Ellen Pramiu; Mauro Carlos Agner Busato; Luiz Carlos Marchi; Adriane Yaeko Togashi
Journal:  Dental Press J Orthod       Date:  2016 Mar-Apr

7.  Ultrastructure of the interface between periodontal tissues and titanium mini-implants.

Authors:  Jaqueline Carvalho Rinaldi; Victor E Arana-Chavez
Journal:  Angle Orthod       Date:  2010-05       Impact factor: 2.079

8.  Assessing double Acid-etched implants submitted to orthodontic forces and used as prosthetic anchorages in partially edentulous patients.

Authors:  Rugani de Cravero Marta; Ibañez Juan Carlos
Journal:  Open Dent J       Date:  2008-03-08

9.  The use of intraosseous screw for upper molar distalization: a case report.

Authors:  Omür Polat-Ozsoy
Journal:  Eur J Dent       Date:  2008-04
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.