Literature DB >> 1813399

Mandibular deformation in subjects with osseointegrated implants.

J A Hobkirk1, J Schwab.   

Abstract

Relative movement and force transmission between osseointegrated (OI) implants in the premolar regions of the edentulous mandible have been measured using intraoral transducers linked to OI implants. These have shown deformations of up to 420 microns and force transmission of up to 16 N as a result of jaw movement from the rest position. Greater displacements and forces were observed in active opening and protrusion than in lateral excursions. There were wide variations from subject to subject, and while the effects of these phenomena are not known, they may be potentially harmful to the interfaces between the implants and bone and the various components of the implant superstructure.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1813399

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  10 in total

1.  An experimental and theoretical composite model of the human mandible.

Authors:  R De Santis; F Mollica; R Esposito; L Ambrosio; L Nicolais
Journal:  J Mater Sci Mater Med       Date:  2005-12       Impact factor: 3.896

2.  Maximum occlusal force and medial mandibular flexure in relation to vertical facial pattern: a cross-sectional study.

Authors:  Rosemary S Shinkai; Fabio L Lazzari; Simone A Canabarro; Márcia Gomes; Márcio L Grossi; Luciana M Hirakata; Eduardo G Mota
Journal:  Head Face Med       Date:  2007-04-02       Impact factor: 2.151

3.  Influence of the implant-abutment connection design and diameter on the screw joint stability.

Authors:  Hyon-Mo Shin; Jung-Bo Huh; Mi-Jeong Yun; Young-Chan Jeon; Brian Myung Chang; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

4.  Mandibular Flexure and Peri-Implant Bone Stress Distribution on an Implant-Supported Fixed Full-Arch Mandibular Prosthesis: 3D Finite Element Analysis.

Authors:  Elena Martin-Fernandez; Ignacio Gonzalez-Gonzalez; Hector deLlanos-Lanchares; Mario Andres Mauvezin-Quevedo; Aritza Brizuela-Velasco; Angel Alvarez-Arenal
Journal:  Biomed Res Int       Date:  2018-04-01       Impact factor: 3.411

5.  Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study.

Authors:  Sara Hussain Alhammadi; Girvan Burnside; Alexander Milosevic
Journal:  BMC Oral Health       Date:  2021-04-01       Impact factor: 2.757

6.  Evaluation of median mandibular flexure values in dentulous and edentulous subjects by using an intraoral digital scanner.

Authors:  Merve Gülsoy; Süleyman Hakan Tuna; Gürel Pekkan
Journal:  J Adv Prosthodont       Date:  2022-02-25       Impact factor: 1.904

7.  The effect of mandibular flexure on the design of implant-supported fixed restorations of different facial types under two loading conditions by three-dimensional finite element analysis.

Authors:  Jing Gao; Xuejing Li; Jing He; Lulu Jiang; Baohong Zhao
Journal:  Front Bioeng Biotechnol       Date:  2022-08-29

8.  Biomechanical considerations on tooth-implant supported fixed partial dentures.

Authors:  Konstantinos X Michalakis; Pasquale Calvani; Hiroshi Hirayama
Journal:  J Dent Biomech       Date:  2012-10-29

9.  Median mandibular flexure at different mouth opening and its relation to different facial types: A prospective clinical study.

Authors:  Mandava Prasad; Mohammed Z Hussain; Sharath K Shetty; T Ashok Kumar; Mohit Khaur; Suja A George; Sameen Dalwai
Journal:  J Nat Sci Biol Med       Date:  2013-07

10.  Elastic deformation of the mandibular jaw revisited-a clinical comparison between digital and conventional impressions using a reference.

Authors:  Alexander Schmidt; Leona Klussmann; Maximiliane A Schlenz; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2021-01-13       Impact factor: 3.573

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.